FUSING/EXIT
6.5.5 PRESSURE ROLLER/CLEANING ROLLER
[A]
[B]
B027R507.WMF
1. Remove the fusing lamp and hot roller assembly. (! 6.5.4)
2. Replace the pressure roller [A] (1 E-ring, 2 bushings, 1 spring).
3. Replace the cleaning roller [B].
NOTE: 1) Apply grease (Barrierta) to the inner surface of the bushing for the
pressure roller.
2) Do not touch the surface of the rollers.
SM
6-21
B089/B093