Ricoh B089 Service Manual page 701

Hide thumbs Also See for B089:
Table of Contents

Advertisement

Address
680576
Number of rings until a call is
detected
680577
Minimum required length of the first
ring
680578
Minimum required length of the
second and subsequent rings
680579
Ringing signal detection reset time
(LOW)
68057A
Ringing signal detection reset time
(HIGH)
68057B
Not used
to
680580
680581
Interval between dialing the last digit
and switching the Oh relay over to
the external telephone when dialing
from the operation panel in handset
mode.
680582
Bits 0 and 1 - Handset off-hook detection time
Bit
1 0 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 2 and 3 - Handset on-hook detection time
Bit
3 2 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 4 to 7 - Not used
680583
Not used
to
6805A0
6805A1
Acceptable CED detection frequency
upper limit (high byte)
6805A2
Acceptable CED detection frequency
upper limit (low byte)
6805A3
Acceptable CED detection frequency
lower limit (high byte)
6805A4
Acceptable CED detection frequency
lower limit (low byte)
6805A5
CED detection time
6805A6
Acceptable CNG detection frequency
upper limit (high byte)
6805A7
Acceptable CNG detection frequency
upper limit (low byte)
SM
Function
3-61
NCU PARAMETERS
Unit
Remarks
1
SP2-103-6
The setting must not be
zero.
20 ms
See Note 4.
SP2-103-7
20 ms
SP2-103-8
20 ms
SP2-103-9
SP2-103-10
Do not change the
settings.
20 ms
Factory setting: 500 ms
Do not change the
settings.
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
20 ms
Factory setting: 200 ms
± 20 ms
BCD (Hz)
If both addresses contain
FF(H), tone detection is
disabled.
B576