Ricoh B089 Service Manual page 638

Hide thumbs Also See for B089:
Table of Contents

Advertisement

ERROR CODES
Code
Meaning
6-10
G3 ECM - error frames still
received at the other end
after all communication
attempts at 2400 bps
6-21
V.21 flag detected during
high speed modem
communication
6-22
The machine resets the
sequence because of an
abnormal handshake in the
V.34 control channel
6-99
V.21 signal not stopped
within 6 s
22-00
Original length exceeded the
maximum scan length
22-01
Memory overflow while
receiving
22-02
Tx or rx job stalled due to
line disconnection at the
other end
22-04
The machine cannot store
received data in the SAF
23-00
Data read timeout during
construction
25-00
The machine software
resets itself after a fatal
transmission error occurred
F0-xx
V.34 modem error
B576
Suggested Cause/Action
• Check for line noise.
• Adjust the tx level (use NCU parameter 01 or the
dedicated tx parameter for that address).
• Check the line connection.
• Defective remote terminal.
• The other terminal may be defective or
incompatible.
• Check for line noise.
• If the same error occurs frequently, replace the
FCU.
• Defective remote terminal.
• Replace the FCU.
• Divide the original into more than one page.
• Check the resolution used for scanning. Lower
the scan resolution if possible.
• Add optional page memory.
• Wait for the files in the queue to be sent.
• Delete unnecessary files from memory.
• Transfer the substitute reception files to an
another fax machine, if the machine's printer is
busy or out of order.
• Add an optional SAF memory card or hard disk.
• The job started normally but did not finish
normally; data may or may not have been
received fully.
• Restart the machine.
• Update the ROM
• Replace the FCU.
• Restart the machine.
• Replace the FCU
• Update the ROM
• Replace the FCU.
• Replace the FCU.