MEMORY ALL CLEAR: SP5801

5.7 MEMORY ALL CLEAR: SP5801
As a rule, you should always print an SMC Report before initializing or adjusting
the SP settings. The SMC Report provides a concise list of all the SP commands
and their current settings. The report can be used for reference if the service
manual is not available.
Executing Memory All Clear resets all the settings stored in the NVRAM to their
default settings except the following:
SP7-003-1:
Electrical total counter value
SP5-811-1:
Machine serial number
SP5-907:
Plug & Play Brand Name and Production Name Setting
1. Execute SP5990 to print out all SMC Data Lists.
2. Open SP5801.
3. Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to
initialize all modules.
No.
What It Initializes
1
All modules
Engine
2
SCS (System
3
Control Service)
/SRM
4
IMH
MCS (Memory
5
Control Service)
6
Copier application
Printer application
8
Scanner application
9
Network application
10
NCS (Network
11
Control Service)
14
DCS
15
UCS
B070/B071
CÓPIA NÃO CONTROLADA
Initializes items 2 ~ 15 below.
Initializes all registration settings for the engine and copy
process settings.
Initializes default system settings, CSS settings, operation
display coordinates.
Initializes the image file system.
Initializes the automatic delete time setting for stored
documents.
Initializes all copier application settings.
Initializes the printer defaults, programs registered, the printer
SP bit switches, and the printer CSS counter.
Initializes the defaults for the scanner and all the scanner SP
modes.
Initializes all service-mode settings about access to the
document server from the DeskTopBinder software on a PC.
For example, initializes the resolution of images the PC gets
using the image converter board option.
Initializes the system defaults and interface settings (IP
addresses also), the SmartNetMonitor for Admin settings,
WebStatusMonitor settings, and the TELNET settings.
Initializes the DCS (Delivery & Receive Control Server) settings.
Initializes the UCS (User Directory Control Server) settings.
5-92
CÓPIA NÃO CONTROLADA