Gestetner B070 Service Manual page 358

Table of Contents

Advertisement

SERVICE CALL CONDITIONS
SC743: Finisher Pressure Plate Motor Error (B468)
Definition [D]
Pressure plate motor operating but the plate is not detected at the home position
within the specified time.
Possible Causes
• Pressure plate HP sensor defective
• Pressure plate HP sensor connection loose or broken
• Pressure plate motor defective
• Finisher main control board defective
• Motor overload
SC744: Finisher Exit Guide Motor Error (B468)
Definition [B]
After moving away from the guide plate position sensor, the exit guide is not
detected at the home position within the specified time (800 ms)
Possible Causes
• Guide plate motor overload
• Motor defective
• Motor harness defective
• Motor connector loose
SC745: Finisher Folder Plate Motor Error (B468)
Definition [D]
The folder plate moves but is not detected at the home position within the specified
time.
Possible Causes
• Folder plate HP sensor defective
• Folder plate HP sensor harness broken or poor connection
• Folder plate motor defective
• Finisher main control board defective
• Motor overload
B070/B071
CÓPIA NÃO CONTROLADA
4-38
CÓPIA NÃO CONTROLADA
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B071

Table of Contents