Finisher, Stapler Entrance Sensors - Gestetner B070 Service Manual

Table of Contents

Advertisement

FINISHER, STAPLER ENTRANCE SENSORS

2.8 FINISHER, STAPLER ENTRANCE SENSORS
Disconnect the finisher from the main unit.
If the Cover Interposer Tray B470 is installed, remove it. Loosen the three shoulder
screws, remove one set screw, then lift it off the frame.
[A]: Finisher entrance sensor bracket ( x 1)
[B]: Finisher entrance sensor ( x 1) ( x 1)
[C]: Stapler entrance sensor bracket ( x 1)
[D]: Stapler entrance sensor and feeler ( x 1)
B468
CÓPIA NÃO CONTROLADA
8
CÓPIA NÃO CONTROLADA
[B]
[A]
[D]
[C]
B468R009.WMF