3.12.7 DUPLEX TRANSPORT SENSOR 1/DUPLEX INVERTER

SENSOR
[F]
[A]
B070R808.WMF
1. Open both front doors and pull out the duplex unit.
2. Both jogger fences ( x 2). (!3.12.6)
3. Right upper duplex cover (!3.12.6).
4. Reverse roller solenoid [A] ( x 1,  x 1, link x 1, spring x 1).
5. Reverse trigger roller assembly [B] ( x 1, bushings x 2,  x 1, links x 1).
6. Left upper cover [C] ( x 2). Slide the left upper cover to the right and remove
it. (The front screw is a shoulder screw.)
7. Duplex inverter sensor [D] ( x 1)
8. Transport sensor 1 [E] ( x 1,  x 1).
Re-assembly
Make sure that the cutouts [F] catch the duplex side plate projections and the
hooks are below the bracket plate.