TRANSFER BELT UNIT

3.9.3 TRANSFER BELT CLEANING BLADE

1. Remove the transfer belt unit. (!3.9.1)
2. Transfer belt cleaning blade [A] ( x 2).
3. Clean the cleaning bias roller [B].
NOTE: Before vacuuming, remove the power pack connectors [C] to protect
the transfer power pack from static electricity.
4. Install the new cleaning blade.
NOTE: Never touch the edge of the cleaning blade. If the setting powder on
the blade edge is accidentally removed at some point, apply setting
powder or toner at that point before installation.
B070/B071
CÓPIA NÃO CONTROLADA
[A]
[B]
3-70
CÓPIA NÃO CONTROLADA
[C]
B070R108.WMF