SERVICE CALL CONDITIONS
SC860: HDD Error 1
Definition [D]
One of the following occurred:
• The HDD is connected, but the driver detected one of the following errors:
SS_NOT_READY
SS_BAD_LABEL
SS_READ_ERROR
SS_WRITE_ERROR
SS_FS_ERROR
SS_MOUNT_ERROR
SS_COMMAND_ERROR
SS_KERNEL_ERROR
SS_SIZE_ERROR
SS_NO_PARTITION
SS_NO_FILE
• The driver could not acquire the status of the hard disks within 30 s.
Possible Causes
• Hard disks are not formatted
• Hard disk corrupted; reformat the disks with SP mode
SC861: HDD Error 2: HDD Startup
Definition [B]
The hard disks were detected at power on, but the disks were not detected within
30 s after recovery from the energy conservation mode.
Possible Causes
• Cable between the hard disks and controller board disconnected or loose
• Hard disk power connector loose
• One of the hard disks is defective
• Controller or mother board defective
B070/B071
CÓPIA NÃO CONTROLADA
One or both HDDs are not ready.
Partition types are different
Error returned during label read or label check
Error returned during label write or label check
File system repair failed
File system mount failed
Drive does not answer the command
Kernel internal error
Driver size is too small
Specified partition does not exist
Device files do not exist
4-48