[B]
6. Front lamp holder [A] ( x 1).
7. Rear lamp holder [B] ( x 1).
8. Three fusing lamps [C] one-by-one.
When re-installing the three fusing lamps, check the following points:
• While aligning the three lamps with the cutouts in the front lamp holder, re-
install the front and rear lamp holders.
• The fusing lamp connectors at the front can be connected in any order.
However, in order to ensure correct fusing temperature control, the
connectors at the back [D] must be connected correctly by matching the color
of the connectors of the fusing unit with the colors of the connection points on
each lamp.
NA
EUR/A
800 W
730 W
560 W
540 W
530 W
530 W
• Route the thermistor cable and thermostat cable correctly. (!3.11.4)
• Make sure that the cables are not pinched and do not contact the gears.
SM
CÓPIA NÃO CONTROLADA
[D]
Connection
Red !" Red
Blue !" Blue
Green !" Green
3-105