3.11.3 HOT ROLLER UNIT, PRESSURE ROLLER

[B]
[C]
[D]
B070R501.WMF
1. Remove the oil supply and cleaning web unit. (!3.11.1)
2. Top cover [A] of the fusing unit ( x 1).
NOTE: When re-installing this cover, align the cutouts [B] and projections [C]
and slide the cover to the right. Make sure that the cover does not
pinch the thermistor and thermostat cables against the stay.
3. Fusing unit inner cover [D] ( x 2).
4. Turn the upper exit guide plate assembly [E] clockwise about 160° and slide the
pivot shaft out of the cutout [F].
5. Release the fusing pressure by turning the pressure lever [G] 1/4 of a turn
counterclockwise with a screwdriver.
CAUTION: Be sure to lock the pressure roller lever [G] before re-attaching
inner cover [D]. The inner cover cannot be re-attached if the
pressure roller lever is not locked.
SM
CÓPIA NÃO CONTROLADA
[A]
[F]
[G]
3-101
CÓPIA NÃO CONTROLADA
FUSING UNIT
[E]