RADVision Scopia Elite 5100 Series Installation Manual page 43

Mcu
Hide thumbs Also See for Scopia Elite 5100 Series:
Table of Contents

Advertisement

b.
Step 7
Select More.
The Local signaling port section is displayed.
Step 8
Enter the number of the signaling port on which the MCU communicates with the SIP server.
The default is 5060.
Step 9
Select Use proxy digest authentication to enable MCU authentication with a SIP server using user
name and password.
Authentication is performed as defined in RFC 2617. This field is disabled by default.
Enter the MCU user name and password. They must match those defined on the SIP server.
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Enter the following information:
The IP address or the host name of the SIP registrar in the IP address field.
The communication port number of the SIP registrar address.
The transport connection type for sending registration requests to the registrar according
to the type supported by the SIP registrar.
The default is UDP.
Figure 5-9
Local signaling port section
Performing the MCU Initial Configuration | 39