Procedure
Step 1
Connect the serial cable from the PC terminal to the serial port on the front panel of the MCU.
Step 2
Connect the power cable.
Step 3
Start the terminal emulation application (such as SecureCRT or PuTTY) on the PC.
Step 4
Set the communication settings in the terminal emulation application on the PC as follows:
Step 5
Turn on the power to the MCU.
A log of the auto-boot events scrolls across the computer monitor.
Step 6
When the message "Please press Enter to activate this console" appears on the screen, press
Enter within 10 seconds.
The network configuration Main menu appears
Caution
If you do not press a key before the countdown ends, the device continues its initialization and you
will need to reboot the device to return to the network configuration Main menu.
Step 7
Enter N at the prompt to configure network port values and press Enter.
Step 8
Enter 2 to change the network configuration.
Step 9
(Optional) Enter Y at the prompt to enable IPv6 in addition to IPv4.
Step 10
(Optional) Enter Y at the prompt to enable IP separation.
Step 11
Enter the IP address you want to assign to the MCU at the IP address prompt and press Enter (see
Figure 5-2 on page
Caution
Do not use leading zeros in the IP address.
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Baud rate: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
31).
(Figure 5-1 on page
Figure 5-1
Main Menu
30):
Performing the MCU Initial Configuration | 30