RADVision SCOPIA Elite 5200 Series Installation Manual

Hide thumbs Also See for SCOPIA Elite 5200 Series:

Advertisement

Quick Links

SCOPIA Elite 5200 Series MCU
Installation Guide
Version 7.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCOPIA Elite 5200 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for RADVision SCOPIA Elite 5200 Series

  • Page 1 SCOPIA Elite 5200 Series MCU Installation Guide Version 7.5...
  • Page 2 If there is any software on removable media described in this publication, it is furnished under a license agreement included with the product as a separate document. If you are unable to locate a copy, please contact RADVISION Ltd and a copy will be provided to you.
  • Page 3: Table Of Contents

    Verifying the Contents ..................6 Inspecting for Damage ..................6 Setting up the SCOPIA Elite 5200 Series MCU Attaching Mounting Brackets on the SCOPIA Elite 5200 Series MCU ......... 7 Chassis Lifting Guidelines................... 8 What to Consider Before Installing the Brackets ............8 How to Install Brackets ..................
  • Page 4 Configuring Protocols for the SCOPIA Elite MCU ............24 Configuring H.323 Protocol Settings............... 24 Configuring SIP Server Settings ..............25 Configuring a Dual-NIC MCU ................28 Table of Contents| ii RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 5 You use the front panel of the MCU for connecting cables and monitoring the unit status. Figure 1-1 Front Panel of the SCOPIA Elite 5200 Series RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5 About SCOPIA Elite 5200 Series | 1...
  • Page 6 The LAN connection is through the upper Media Blade. The lower Media Blade functions as the slave. Figure 1-2 Media Blade of the SCOPIA Elite 5200 Series About SCOPIA Elite 5200 Series | 2 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 7 900 rpm. PWR ALARM LED Lights red if there is a failure in one of the AC power supplies. About SCOPIA Elite 5200 Series | 3 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 8: How To Prepare For Scopia Elite 5200 Series Mcu Installation

    Inspecting for Damage ................. page 6 About Site Preparation Prior to installing the SCOPIA Elite 5200 Series MCU, you need to verify that your site is suitable for the MCU. Read this section to learn about the product technical specifications and site requirements.
  • Page 9: Unpacking The Scopia Elite 5200 Series

    To prevent injury and equipment damage, follow lifting guidelines described in the Safety Guide when lifting or moving the shipping box. How to Prepare for SCOPIA Elite 5200 Series MCU Installation | 5 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 10: Verifying The Contents

    If you suspect any damage from shipping, contact your local freight carrier for procedures on damage claims. If you observe any physical defects in the items you ordered, contact RADVISION Technical Support for Return Material Authorization (RMA) form.
  • Page 11: Setting Up The Scopia Elite 5200 Series Mcu

    Setting up the SCOPIA Elite 5200 Series MCU • Attaching Mounting Brackets on the SCOPIA Elite 5200 Series MCU ....page 7 • Chassis Lifting Guidelines..............page 8 • What to Consider Before Installing the Brackets........... page 8 • How to Install Brackets ................ page 9 •...
  • Page 12: Chassis Lifting Guidelines

    What to Consider Before Installing the Brackets When planning your rack installation, consider the following guidelines: • Install the SCOPIA Elite 5200 Series MCU in an open rack whenever possible. If installation in an enclosed rack is unavoidable, ensure that the rack has adequate ventilation. •...
  • Page 13: How To Install Brackets

    Mount Kit Description................page 10 • Adjusting the Bracket Length ..............page 11 • Installing the Brackets................. page 12 Setting up the SCOPIA Elite 5200 Series MCU | 9 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 14: Mount Kit Description

    Right integral mounting bracket • Left integral mounting bracket • Four hexagon socket cap screw M6×10 (Din 7984) Setting up the SCOPIA Elite 5200 Series MCU | 10 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 15: Adjusting The Bracket Length

    For each bracket, slide the two bracket parts until the round hole meets the elliptic hole corresponding to the depth of the rack. Step 3 Insert the Allen screw where both holes meet. Setting up the SCOPIA Elite 5200 Series MCU | 11 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 16: Installing The Brackets

    Locate the holes in the rack post mounting strips, that you have selected to attach the brackets and make sure that they are all at the same height. Figure 3-5 Rack Post Mounting Strips Setting up the SCOPIA Elite 5200 Series MCU | 12 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 17: Rack Mounting The Scopia Elite 5200 Series Mcu

    Attaching the System Ground Before connecting power or turning on power to the SCOPIA Elite 5200 Series MCU, it strongly recommend that you provide an adequate chassis ground (earth) connection for the chassis.
  • Page 18: Shelf Mounting The Scopia Elite 5200 Series Mcu

    On the rear side of the MCU, power on the MCU using the On/Off switch. Turn on the power distribution unit (PDU). Setting up the SCOPIA Elite 5200 Series MCU | 14 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 19: Verifying Scopia Elite 5200 Series Mcu Installation

    The Control Blade LEDs Step 2 On the front panel, verify that the STATUS LED is lit green. Setting up the SCOPIA Elite 5200 Series MCU | 15 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 20 The MCU creates the conference and you see the Conference window. Exit the conference by disconnecting the call. Setting up the SCOPIA Elite 5200 Series MCU | 16 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 21: Performing Initial Configuration Of The Scopia Elite Mcu

    Setting the IP Address for Both Blades You use the serial port on the SCOPIA Elite 5200 Series MCU front panel to assign a new IP address to your MCU. You must assign the IP address before you connect the MCU to the network.
  • Page 22 Do not use leading zeros in the IP address and ensure both IP addresses must be on the same subnet. Performing Initial Configuration of the SCOPIA Elite MCU | 18 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 23: Accessing The Scopia Elite 5200 Series Mcu Administrator Interface

    The default language of the MCU interface is English. When you access the MCU interface, the login screen is in English unless you choose a different language. Performing Initial Configuration of the SCOPIA Elite MCU | 19 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 24: Changing A User Password

    Changing a User Password Only administrators can change a password. The SCOPIA Elite 5200 Series MCU comes with two preconfigured users: an administrator and an operator. The password for both preconfigured users is ‘password’. We highly recommend that you change the default user password for security.
  • Page 25: How To Set The Mcu's Interface Languages

    SCOPIA Elite MCU supports the same languages for the Administrator and Conference Control interfaces, and a different set of languages for the text overlay. Performing Initial Configuration of the SCOPIA Elite MCU | 21 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 26: Setting The Mcu's User Interface Language

    Select Configuration in the MCU user interface. The Setup tab is displayed. Step 2 Locate the Basics section. Performing Initial Configuration of the SCOPIA Elite MCU | 22 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 27: Setting A Text Overlay Language

    Select the required language. Figure 4-2 The Video display messages Section of the Customize Tab Step 4 Select Apply. Performing Initial Configuration of the SCOPIA Elite MCU | 23 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 28: Configuring Protocols For The Scopia Elite Mcu

    The Status tab of the Administrator interface opens. Locate the Status Map section. This section is a graphic representation of the MCU chassis Performing Initial Configuration of the SCOPIA Elite MCU | 24 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 29: Configuring Sip Server Settings

    Verify that the MCU is connected to the Gatekeeper. Configuring SIP Server Settings You can configure settings for SIP server profiles which set how the SCOPIA Elite 5200 Series MCU and the registrar interact. Depending on connection types supported by the SIP server, MCU supports these transport connection types for sending messages to SIP server: •...
  • Page 30 To instruct the MCU to register with a SIP registrar and to send service information to the registrar, perform these steps: Select Use registrar. Performing Initial Configuration of the SCOPIA Elite MCU | 26 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 31 Check the MCU status using the MCU Administrator interface: Enter the MCU IP address or the MCU name into the Internet browser. Performing Initial Configuration of the SCOPIA Elite MCU | 27 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 32: Configuring A Dual-Nic Mcu

    Dual-NIC functionality requires two subnets, where each subnet must have its own router or default gateway. Performing Initial Configuration of the SCOPIA Elite MCU | 28 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 33 Under Management Interface, enter the IP information for the management subnet: Enter the MCU’s IP address on the management subnet in the Primary IP address field. Performing Initial Configuration of the SCOPIA Elite MCU | 29 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 34 29), to open the Additional Management Networks section. Enter the IP address of the additional subnet’s router. Performing Initial Configuration of the SCOPIA Elite MCU | 30 RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5...
  • Page 35 F +44 20 3178 5717 F +852 2801 4071 infoUSA@radvision.com infoUK@radvision.com infoAPAC@radvision.com This document is not part of a contract of license as may be expressly agreed RADVISION is registered trademarks of RADVISION, Ltd. All trademarks recognized. All rights reserved © 2010 RADVISION, Ltd.

Table of Contents