Replacing a power supply module

Your server uses hot-swappable, redundant power supplies. If one of the two power supplies
fails, the other power supply module supports the server while you replace the failed
module. You do not need to turn off the server or disconnect peripheral devices to replace
a failed power supply module.
If you are adding a redundant power supply module to your server, you must update the
FRU/SDR after the installation is complete. For more information, see
FRU/SDR" on page
Warning
To replace a power supply module:
1
Examine the LED indicators on the back of each power supply module to identify
the failed module. The power supply module has failed if the orange (right) LED
indicator is on.
Shipping
screw
Power
on LED
2
Unplug the power cord from the failed power supply module.
3
Remove the shipping screw (if installed).
37.
The power supply modules in this server contain no user-serviceable
parts. Only a qualified computer technician should service the power
supply modules.
Your server comes with 3-wire AC power cords fitted with the correct
plug style for your region. If this plug does not match the connector
on your surge protector, UPS, or wall outlet, do not attempt to modify
the plug in any way. Use a UPS or wall outlet that is appropriate for
the supplied AC power cords.
www.gateway.com
Replacing a power supply module
"Updating the
Power supply
fault LED
81