Chapter 4: Installing Components
2
If a drive has failed, determine which drive has failed by running storage console
software.
SCSI Drives - Match the software's SCSI ID for the failed drive with the SCSI ID number
to the left of the hot-swap bays.
SATA Drives - Match the indicated drive or port number for the failed drive with the
controller card or connector, as well as the connector and cables on the back of the
drive cage, to determine which drive has failed. See the system label inside your server
for information on identifying the SATA connector and the corresponding drive.
Caution
60
Before you remove a failed drive, use the appropriate software and
utilities installed on the server to stop all activity on the failed drive.
Instructions for using the software are provided by the software
manufacturer. Failure to do so may destroy the data on the drive.