Backlight; Cartridges (Used By Standard Horizon Technicians); Internal Data Base Test; Sd Card Test - Standard Horizon CPN700i Owner's Manual

Multimedia chart plotters
Hide thumbs Also See for CPN700i:
Table of Contents

Advertisement

9.1.2

BACKLIGHT

Each time you move the
move it to the right to increase brightness.
9.1.3

CARTRIDGES (USED BY STANDARD HORIZON TECHNICIANS)

Internal Data Base Test

To test the Worldwide Background.

SD CARD Test

To test the SD CARD. There are the possible situations:
1. If there is an SD CARD inserted in the slot and there is not a malfunction, the name of
the SD CARD zone and the message "OK" are shown.
2. If there is an SD CARD inserted in the slot, but it is a defective SD CARD, the name of
the SD CARD zone and the message "Faulty" are shown.
3. If there is not any SD CARD inserted in the slot, the message "not present" is shown.
9.1.4

SERIAL PORTS (USED BY STANDARD HORIZON TECHNICIANS)

If you are having problems receiving data from the position-finding instrument, this test
should help determine the problem.

Change Parameters

To change the parameters of the serial interface. This menu allows selecting the Port
(Signal Source) between Port1, Port2, Port3, Port4; the Baud Rate between 300, 1200,
2400, 4800, 9600, 38400, 115200; the Data Bits (Word Length) between 7 or 8, the Parity
between even, odd or none, the Stop Bits between 1 or 2. Default settings are: Port =
PORT2, Baud Rate = 4800, Data Bits = 8, Parity = none, Stop Bits = 1.

Input Data Display

To allow the CPN Series Chart Plotter to act as a computer terminal and display the
incoming data exactly as it is received. If the data displayed on the screen is unrecognizable,
you may have selected the wrong input parameters for your particular receiver, for example,
Baud Rate 9600 instead of Baud Rate 4800. Check your receiver manual to be sure that
you have selected the proper parameter. If the screen is blank, you may have a broken
connection, and no data is being received or you may have connected the device to the other
input port. Use the
ShuttlePoint knob to show data in hex or ASCII mode and the

Loop-Back Test

This is a special test done during the production phase to check the serial ports integrity.
A special connector is required.
Page 172
ShuttlePoint knob to the left, the screen will decrease brightness,
key to stop (or continue after pausing) data displaying, press the
key to exit.
Owner's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpn1010i

Table of Contents