Perform a soft reset of the switcher as follows:
1.
Use an Extron tweeker or other small screwdriver to press and hold the
Reset button until the Reset LED blinks once (for events reset), twice (for IP
settings), or three times (for absolute reset) (figure 3-32).
2.
Release the Reset button and then immediately press and release the Reset
button again. Nothing happens if the second momentary press does not occur
within 1 second.
LAN
Events Reset
LAN
IP Settings Reset
LAN
Absolute Reset
Figure 3-32 — Whole switcher and absolute resets
ISS 506 Integration Seamless Switcher • Operation
Press and hold
the Reset button.
3 seconds
1
RESET
RESET
Reset LED flashes once.
Press and hold
the Reset button.
6 seconds
2
RESET
RESET
Reset LED flashes twice.
Press and hold
the Reset button.
9 seconds
3
RESET
RESET
Reset LED flashes three times.
Release, then
immediately
press and release again.
RESET
Release, then
immediately
press and release again.
RESET
Release, then
immediately
press and release again.
RESET
3-39
Need help?
Do you have a question about the ISS 506 and is the answer not in the manual?