11.1

JMA-5212-4/6 TYPE RADAR

(1) Class of emission
(2) Display
(3) Screen
(4) Range Scale
(5)
Range Resolution
(6) Minimum Detective Range
(7) Range Accuracy
(8) Bearing Accuracy
(9) Bearing Indication
(10) Ambient Condition
(11) Power Supply Input
(12) Power Consumption
(13) Power Supply Voltage
Fluctuation
(14) Pre-heating Time
P0N
Color Raster Scan, PPI Method
15-inch Color LCD
Effective diameter of radar display, more than 180 mm
0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48, 96 nm
Less than 30m
Less than 40m
Less than 1% of the maximum distance of the range scale in use or
less than 15m whichever is larger
Less than 1°
Relative Motion mode: Head-up/Course-up/North-up
True Motion mode:
According to IEC60945-4
Temperature
Scanner:
(Storage Temperature:
Other Unit except Scanner: -15 to +55°C
Relative Humidity
93% at +40°C
Vibration
2 to 13.2Hz, amplitude ±1mm ±10%
13.2 to 100Hz, acceleration 7m/s
Velocity of the wind
51.5m/s (100kt)
+24VDC (Display Unit)
+24VDC (Scanner)
Display Unit and Scanner correspond to
100/110/115/220/230/240VAC, 1M, 50/60Hz
when use NBA-5111.
Approx. 600W (In maximum wind velocity)
+24VDC –10/+30% (Display Unit)
+24VDC –10/+30% (Scanner Unit)
Approx. Within 1min30sec
11 1
Course-up/North-up
-25 to +55°C
-25 to +70°C)
2