Gyro Set Alarm; Ais Alarm Display - JRC JMA-5212-4/6 User Manual

Hide thumbs Also See for JMA-5212-4/6:
Table of Contents

Advertisement

System Function Alarm (TT Data)
When an abnormal state of an input signal or Target Tracking unit may have a trouble, alarm is generated.
When an alarm occurs against any Target Tracking function, TT (Data) will appear in the alarm indication
(Software button
Tracked Target information display (panel display area in Section 2.3.8). This status means that there is any
operational trouble in the Target Tracking unit. Please, contact the service depot or the manufactures.
Alarm characters
TT (DATA)

Gyro Set Alarm

The GYRO I/F in this system receives signals from a gyro. Even if the power is turned off, the system will
follow up the gyro. However, the system stops the follow-up operation when the power of the master gyro is
turned off or when any trouble occurs to the line. When the power of the master gyro is recovered, the
Set Gyro alarm will be generated.
If this alarm occurs, set the gyro.
Alarm characters
Set Gyro

AIS Alarm Display

The following provides a list of the AIS alarm.
Alarm No.
001
Tx malfunction
002
Antenna VSWR exceeds limit
003
Rx channel 1 malfunction
004
Rx channel 2 malfunction
005
Rx channel 70 malfunction
006
general failure
008
MKD connection lost
025
external EPFS lost
026
no sensor position in use
029
no valid SOG information
030
no valid COG information
032
Heading lost/invalid
035
no valid ROT information
located at the operation/message area in Section 2.3.9), but no indication is made in the
System Function Alarm
Alarm sound
Beep sound (pipipi)
Alarm
acknowledgeable
Gyro Set Alarm
Alarm sound
Beep sound (pipi-pipi)
An alarm sound is generated when a Target Tracking
circuit error occurs.
The signals from the gyro are stopped, but the gyro is
recovered.
Definition
5 67
Conditions
Conditions

Advertisement

Table of Contents
loading

Table of Contents