To calibrate from the LCD:
Step 1:
Select the channel of the scroller you wish to calibrate.
Step 2:
Press the [Color] encoder button to the upper right of the LCD. Multiple presses may
be required before the scroller encoder is visible in the virtual encoder display.
Step 3:
Use the encoder to move all the way to the last frame of the scroller.
Step 4:
Watch the scroller and continue adjusting the frame until it is centered in the desired
position.
Step 5:
Press and hold the scroller encoder. {Calibrate} becomes visible as a softkey in the
encoder LCD.
Step 6:
Press {Calibrate}. The new center position is now stored for the selected channel.
Step 7:
Continue holding the encoder and press {Last} to move to the center point of the
previous frame.
Step 8:
Visually verify if the center point of the new frame is accurate. If it is, press {Last}
again to move to the previous frame in the scroll. If not, follow the calibration
procedure again.
Step 9:
Repeat steps 6-9 until you have calibrated all of the frames.
5