[Record Only] is similar to [Record] except that it selectively stores only manually set values,
preventing unwanted levels (such as from a submaster or another cue list), from being recorded
into the cue. Therefore, when used to record a cue, only the manual data for channels will be stored
in the cue. Any values in the previous cue that were unchanged will track into the new cue.
All of the same commands used for [Record] may also be used for [Record Only].
• [Record Only] <Cue> [Next] [Enter] - stores only the manually set values into the next cue
in the list.
• [Record Only] [Cue] [3] [Enter] - stores only the manually set data into cue 3.
• [2] [thru] [8] [Record Only] <Cue> [9] [Enter] - stores only the manually set data for
channels 2 through 8 into the target cue 9.
• [Group] [2] [Record Only] [Cue] [5] [Enter]- stores only the manual data from group 2 into
cue 5.
• [selected channels] {Color} [Record Only] <Cue> [4] [Enter] - stores only the color data for
the selected channels into cue 4.
As with [Record], filters can further restrict stored data if deployed when using [Record Only].