Create new zero Create new Tare level level Actual Low level Speed bar Actual High level maximum Actual recipe Actual production speed Actual status Return to Select/edit recipe main menu Start controller in run mode ETC | Explanation of production screen.
Output Output Output Check Check Reject Reject Dosing Used Used High Busy Mode Ready Digital Inputs: Input 1: Start (option) Input 2: Stop (option) Input 3: Start Check Input 4-8: Not used ETC | Wiring connection for Flex-CK model Flex-2100.
The Configuration and System setting are locked by a password, log-in with the Log-in button first. To log-out, press the Log-out button. The overall password is “25630”. Screen if Configuration and System settings are disabled: System Log-in Screen if Configuration and System settings are enabled: System Log-out ETC | Selection Menu.
Press the “Edit” button to type the exact reference weight in the Calibrate a gain point “Add/Replace” field. (Reference weight) To save the reference weight, press the “ + activate button”. In the calibration menu The reference weight is calibrated now. ETC | First use of the indicator.
“+Activate” button to save the zero point Press “EDIT” and put a reference weight on the weigher. Enter the weight of the reference weight and press OK. To save the second point, press the “+Activate” button. ETC | Calibration.
Press the “OK” button to return to the previous screen and save the settings. Open parameter Factory settings: Edit parameters information Stability :OFF Hold time :0.00 sec (disabled) Display hold time :2.00 sec Max. Speedbar :120 pcs/min Password :0 (disabled) Quit without Quit and save saving ETC | Setup the Checkweigher configuration.
To edit a recipe Press the recipe number in the gray fields. To enter the recipe edit screen the user must be logged in. To return to the production screen without changes, press the “Return” button. Edit Recipe Select Recipe Scroll bar Return to Production screen ETC | Select/Edit Recipe.
To return to the previous screen and save the recipe, press the “Return” button. Open parameter Edit Recipe information name Edit Recipe parameter Scroll bar Return to Previous screen Use the scroll bar to enter the next values. ETC | Edit Recipe parameters.
To reset the totals and subtotals, press the “Total” button. Press the Question marks to open information about the parameter. To return to the previous screen, press the “Return” button. Open parameter information Return to Previous screen Reset sub totals Reset totals ETC | Production data.
WEIGHT CONTROLLER TYPE FLEX CHECK/CATCH September 1, 2011 WEIGHER Information. To view the Penko contact information, press the “information” button from the selection menu. ETC | Information.
No, to point 9 b. Yes, start delay time high 9. If weight OK, output OK ON 10. Check busy OFF 11. Dosing ready ON. 12. Wait till input start OFF. 13. Dosing ready OFF. 14. Restart. ETC | Sequence example.
Need help?
Do you have a question about the PENKO Flex and is the answer not in the manual?