Analog Inputs and Relay Outputs

A n a l o g I n p u t s
Analog inputs are available on the Ion.Each analog event in the event list consists of a port address
and an action. There is a global enable for all analog inputs in Setup, see
You will also need to configure set the group and address for the port. See
trigger connector), page
A n a l o g I n p u t E v e n t s
Analog Input events fire when the analog input passes a certain level. Action types supported are
the same as Time Code; run a cue, control a submaster, and fire a macro.
Create an Analog Input Event where an input on address 1 will fire Cue 10.
If you select the submaster option, you will have an additional option of fader, which will map the 0-
10v input to the level of a specified submaster.
R e l a y O u t p u t s
Relay outputs are available on the Ion. Relay outputs are also often called remote triggers, contact
closures, or contact outputs. To configure, see
Relay outputs are controlled by external links in cues. See

MIDI Show Control

Ion has two MIDI ports on the rear of the console. For configuring the ports. see
D a t a S o u r c e s
MIDI Show Control (MSC) receives data from a MIDI input source. There are 32 available MIDI
sources, numbered 1-32. MIDI consists of many types of data, but MSC looks only at MSC data.
Other MIDI transmitted data is ignored by MSC.
M I D I S h o w C o n t r o l D e v i c e s
MIDI Show Control data carries a device ID within the data packet. MSC setup allows for the
specification of two device IDs: one for reception and one for transmission.
Only MSC data with the correct receive device ID, or an ALL CALL ID, will be interpreted by Ion.
All outgoing MSC data contains the specified transmit device ID within.
24
Using Show Control
305.
<Event> [4] [/] [1] {Address} [1] [Cue] [1] [0] [Enter]
Relay Out (remote trigger connector), page
Using the Execute List, page
Show Control, page
98.
Contact Closure (remote
305.
164.
MIDI, page
305.
283