B. Gaining Access to the "Define Outputs" Mode
& Upon gaining access to the installer menu (see Section
1), the display will read "1. NEW INSTL CODE".
& Click <NEXT> until the 6th mode is displayed:
6 . D E F I N E O U T P U T S
& Click <OK>. The display will show the first sub-mode:
D E F I N E P G M
There are two sub-modes: DEFINE PGM and DEFINE
X-10. You can toggle between them by clicking <NEXT>.
C. Programming Multiple-Choice Locations
If a multiple choice location is selected, its name will be
displayed as shown in this example:
S E T H O U S E C O D E
A few options are available, but once you click <OK>, the
currently saved option will be displayed with a dark
selection box at the far right:
h o u s e c o d e = A
If you approve of this option, click <OK>. The "Happy
Tune" will sound (- - - –––) and the display will revert to its
previous state ("SET HOUSE CODE" in this case).
If you do not approve, review the other options by clicking
<NEXT> repeatedly. Options that are not saved will have a
clear space at the far right, as shown:
h o u s e c o d e = B
To select an option that is not currently saved, click <OK>.
A dark box will appear at the far right. Clicking <OK> once
more will cause your selection to be saved - the "Happy
tune" will sound and the display will revert to its previous
state ("SET HOUSE CODE" in this case).
D. Programming Numerical Data Locations
In case of a numerical data location, refer to the detailed
procedure given in the following paragraphs.

7.2 PGM Output Control

Here you determine which factors will activate the PGM
output. The available options are:
& on by arming: ON upon arming and OFF upon
disarming.
& on by memory: pulsating ON/OFF upon registration of
an alarm in the memory; steadily ON after disarming and
OFF upon clearing the memory indication.
& on by delay: ON during the exit and entry delays.
& on by keyfob: ON by pressing the AUX (fourth) button
of a keyfob transmitter - provided that "PGM/X-10" is
selected in location 16 of the "Define Panel" menu. The
duration of activation depends on the option selected in
location 20 of the "Define Panel" menu.
& on by timer: ON and OFF at specific preset times.
& on by zones: ON by triggering a sensor in any one of
3 selected zones, irrespective of arming / disarming. The
duration of activation depends on the option selected in
location 20 of the "Define Panel" menu.
Note: The PGM output may be programmed for
activation by any combination of factors.
A. Upon clicking <OK> while "6. DEFINE OUTPUTS" is
shown, the display will change to:
D E F I N E P G M
16
B. Click <OK>. The display will change into:
O N B Y A R M I N G
C. Select the desired option (YES or NO) as outlined in
Para. 7.1 C above. When done, click <NEXT> to select
the next item on the menu.
D. Go through the next 3 menu items (ON BY MEMORY,
ON BY DELAY and ON BY KEYFOB), selecting the
desired option for each. After that, clicking <NEXT> will
change the display into:
O N B Y T I M E R
E. Click <OK>. The display will read:
s t a r t -
H H : M M A
F. Click <OK>. The display will change to:
s t a r t -
0 0 : 0 0 A
G. Enter the time at which you wish the output to be
activated.
Note: AM and PM are selected by clicking "✶" and "#",
respectively.
Once the time on display is correct, regardless of the
cursor position, click <OK> twice. The happy tune will
sound and the display will revert to: "start - HH:MM"
H. Click <NEXT>. The display will now read:
s t o p -
H H : M M P
I. Click <OK>. The display will change to:
s t o p -
0 0 : 0 0 P
J. Enter the time at which you wish the output to be
deactivated. Once the time on display is correct,
regardless of the cursor position, click <OK> twice. The
happy tune will sound and the display will revert to
"stop - HH:MM"
K. Click <HOME> to return to "ON BY TIMER" and then
<NEXT>. The display will show:
O N B Y Z O N E S
L. Click <OK>. The display will read:
a - z o n e
M. Click <OK>. The display will change to:
a - z o n e
N. Enter the number of the first zone that you designate
for activating this output, and then click <OK>. The
display will revert to "a - zone".
O. Click <NEXT> to select "b - zone" and repeat steps L
through N for the second zone. When done, the display
will revert to "b - zone".
P. Click <NEXT> to select "c - zone" and repeat steps L
through N for the third zone. When done, the display
will revert to "C - zone".
Q. Click <HOME> to return to "ON BY ZONES" and then
<HOME> again. The display will show:
D E F I N E P G M
R. Click <NEXT> to select the "DEFINE X-10" sub-mode
and then continue as in 7.3 below.

7.3 Controlling the X-10 Units

Here you can perform the following programming actions:
• Select the house code (a code letter from A to P that
will distinguish the site in which the system is installed
from other sites in the neighborhood).
_ _