Enter "7:BROADBAND", select the menu to configure (see guidance above and in section 5.6.1), then refer to the
table below for configuration instructions.
Option
DHCP Client
MANUAL IP
→ → → →
IP ADDRESS
→ → → →
SUBNET MASK
→ → → →
DEFAULT GW
RESET MODULE

5.7 PGM Output

5.7.1 General Guidance

The "05:OUTPUTS" menu enables you to select events/conditions under which the PGM (programmable) output will
function and to select the internal siren or STROBE light (that will be activated according to system programming).
⋅ ⋅ ⋅
05:OUTPUS
Enter "PGM DEVICE 01", select the menu you wish to configure (see guidance above and in section 5.2), and then
refer to the table in section 5.7.5 for configuration instructions.
Note: PGM not to be enabled in UL Listed Product.

5.7.2 Open Collector States

The PowerMaster provides an open collector output (active low) for control:
ON state (pulled to ground) = 0
OFF state:
no pullup = float
with pullup to Vcc = 1

5.7.3 Configuring a PGM device

Define which factors, including any combination of factors, will determine the PGM output.

5.7.4 Entering Daytime Limits

⋅ ⋅ ⋅
05:OUTPUS
Enter the "LOCKOUT TIME" menu and enter the daytime limits through which the PGM device will turn off, even when
the associated sensors are triggered.

5.7.5 PGM Output Configuration

Option
PGM: BY ARM AWAY
PGM: BY ARM HOME
PGM: BY DISARM
PGM: BY MEMORY
1
In PowerMaster-10 G2, this is always available. In PowerMaster-30 G2, this is optional only when the expansion module is installed.
2
Soak Test is not applicable for UL installations
D-304762 PowerMaster-10/30 G2 Installer's Guide
Configuration Instructions
Define whether to obtain an IP address automatically using a DHCP server or to enter an
IP address manually.
Options: Disable (default); Enable.
Manually enter LAN parameters.
Enter the IP address of the Broadband Module
Enter the subnet mask used with the IP address.
Enter the default gateway of the Broadband Module.
Note: If DHCP Client is set to Enable, the entries for IP ADDRESS, SUBNET MASK and
DEFAULT GW will be ignored.
Determine whether to reset the broadband module (REBOOT) or to reset all broadband settings –
does not reset Monitoring Station IP settings. (FACTORY DEFIN.).
PGM DEVICES
PGM DEVICES
Configuration Instructions
Determine to activate the PGM output upon arming Away / Home / Disarm.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Determine to activate the PGM output upon registration of an alarm in the memory. The
output will restore to normal upon memory clearing.
Options: disable (default); turn ON; turn OFF; activate PULSE.
Note: In Soak Test mode
activated.
⋅ ⋅ ⋅