Receiver Type: Super-heterodyne, fixed frequency
Receiver Range: 600 ft (180 m) in open space
Antenna Type: Spatial diversity
Coding: PowerCode and/or CodeSecure™

2.3 Electrical Data

Power Supply: Internal switching power supply 100VAC
to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
Current Drain: Approx. 40 mA standby, 1400 mA at full
load.
Site External Siren Current (EXT): 450* mA max @ 10.5
VDC minimum when powered by AC & DC (battery).
Site Internal Siren Current (INT): 450* mA max. @ 10.5
VDC minimum when powered by AC & DC (battery)
PGM Output Current: 100* mA max.
Wired Detectors (zones 29&30) Total (Sum) Current:
450* mA max.
High Current / Short Circuit Protection: All outputs are
protected (automatic reset fuse).
* Total PowerMaxComplete output current (of INT & EXT
sirens, PGM output and detectors) must not exceed 550
mA for 9.6V battery and 450 mA for 7.2V battery.
Backup Battery Options:
Maximum external devices current
1300 mAh
6 Battery
(2)
Pack
4h
210mA
8h
90mA
12h
45mA
24h
0mA
36h
(no backup)
48h
(no backup)

3. INSTALLATION

3.1 Unpacking the Equipment

Open the cardboard packing box and check whether all
items have been included. If you find out that an item is
missing, contact your vendor or dealer immediately.

3.2 Supplying Power to the Unit

Connect power to the PowerMaxComplete temporarily
(see figure 3.10). Alternatively, you may power up from the
backup battery, as shown in figure 3.3.
Disregard any "trouble" indications pertaining to lack of
battery or lack of telephone line connection.
3.3 System Planning & Programming
It pays to plan ahead - use the tables in appendices A and
B at the end of this guide to register the intended location
of each detector, the holder and assignment of each
transmitter.
D-303983 PowerMaxComplete Installer's Guide
(1)
1800 mAh
2200 mAh 8-
8-Battery
Battery Pack
(3)
Pack
300mA
380mA
160 mA
200mA
90 mA
120 mA
25 mA
45mA
5mA
15mA
(no backup)
0mA
1
Devices that are connected between 12V terminal
and GND of PowerMaxComplete, that includes
internal GSM and proximity reader.
2
7.2V 1300 mAh, rechargeable NiMH battery pack,
p/n GP130AAH6BMX, manufactured by GP.
3
9.6V 1800 mAh, rechargeable NiMH battery pack,
p/n GP180AAH8BMX, manufactured by GP.
4
9.6V 2200 mAh, rechargeable NiMH battery pack
(special order).
Maximum battery recharge time: 72 hours
Battery Test: Once every 10 seconds.

2.4 Communication

Built-in Modem: 300 baud, Bell 103 protocol
Data Transfer to Local Computer: Via RS232 serial port
Report Destinations: 2 central stations, 4 private
telephones.
Reporting Format Options: SIA, Pulse 4/2 1900/1400 Hz,
Pulse 4/2 1800/2300 Hz, Contact ID, Scancom.
Pulse Rate: 10, 20, 33 and 40 pps - programmable
Message to Private Phones: Tone or voice
Ring Detection: The unit does not support ring detection
without DC voltage present on the telephone lines.

2.5 Physical Properties

Operating Temp. Range: 14°F to 120°F (-10°C to 49°C)
Storage Temp. Range: -4°F to 140°F (-20°C to 60°C)
(4)
Humidity: 85% relative humidity, @ 30°C (86°F)
Size: 266 x 206 x 63 mm (10-7/16 x 8-18 x 2-1/2 in.)
Weight: 1.44Kg (3.2 pounds) (with battery)
Color: White
Gather up all transmitters and detectors used in the
system and mark each one in accordance with your
deployment plan.
Program the system now as instructed in the
programming section.

3.4 Mounting

Required tool: Philips screwdriver #2.
PowerMaxComplete mounting process is shown in figure
3.1 - 3.11.

3.5 Wiring

Required tools: Cutter and slotted screwdriver - 3 mm
blade.
PowerMaxComplete wiring is shown in figure 3.2.