Matrix Vision System Manual page 98

Table of Contents

Advertisement

Matrix
Code Meaning
0
Voice Guidance for DID deactivated.
1
Voice Guidance for DID activated.
Use following command to activate Voice Guidance for DID on all trunks during night time:
3504-*-Code
By default, Voice Guidance for DID is ON on all trunks during day time and night time.
Step 5
Use following commands to set the various timers:
Timer Name
DID Inactivity Timer
DOSA/DID Answer Wait Timer
DOSA/DID Music Timer
DOSA/DID dial tone time and DOSA/DID Beeps Timer
DID Ring Timer
DOSA/DID Busy Tone Timer
DOSA/DID Error Tone Timer
DID Inactivity Timer:
• It signifies the time after which the system disconnects the trunk call if not replied by any station. To
elaborate, When a DID call arrives to a system , the system attends the call after DID answer wait timer. If no
digit is dialed then the call goes to the landing destination. The system waits for the call to be answered by a
station for DID Inactivity timer. On expiry of the DID inactivity timer, the system disconnects the call.
DOSA/DID Answer Wait Timer:
• It signifies the time after which the system answers a DID call.
DOSA/DID Music Timer:
• It signifies the time for which the system plays music after answering the call.
DOSA/DID Dial Tone Timer:
• It signifies the time for which the system gives dial tone to the caller to dial a station number.
DOSA/DID Beeps Timer:
• It signifies the time for which the system gives beeps to the caller to grab the trunk line or dial the station
name. This timer is same as DOSA/DID Dial Tone Timer.
DID Ring Timer:
• It signifies the time for which the station rings when reached through DID.
DOSA/DID Busy Tone Timer:
• It signifies the time for which the system gives busy tone to the caller if the station dialed by the caller is busy.
DOSA/DID Error Tone Timer:
• It signifies the time for which the system gives error tone to the caller if the caller dials invalid codes.
Example:
Activate DID for a trunk (Software port number 2) during Day time and Night time.
3501-1-2-1
3502-1-2-1
98
Command
Default (in sec.)
3022-Seconds
3023-Seconds
3024-Seconds
3025-Seconds
3026-Seconds
3027-Seconds
3028-Seconds
Valid Range
60
000 to 255
05
000 to 255
05
000 to 255
10
000 to 255
30
000 to 255
05
000 to 255
05
000 to 255