Table 5-2. Operator Display Messages (Continued)
Display
Probable Cause
The 9840 Tape Drive cannot write
DmpWrFail1
diagnostic data onto the tape.
The 9840 Tape Drive cannot
position the tape.
There is no diagnostic dump data
DmpWrFail2
to process.
The 9840 Tape Drive detected the
DumpAgain?
same Chk (FSC) within a minute.
The cleaning cartridge is spent.
Exp ClCart
Alternates with and "*" (asterisk)
FFFF:Dmp Y
after completion of IPL, where
FFFF=the FSC of last dump data
collected and Y=number of
uncollected dumps in EEPROM.
The checksum does not match
Fix CfgErr
after an IPL.
An initialization error occurred.
Init (FSC)
After the IPL switch is pressed,
IPL Pend
the IPL is pending.
The common controller code is
Load CC
loading.
Normal display during IPL.
Load ESCON
Cartridge tape is being loaded.
Loading
The load or unload operation
Load (FSC)
failed.
Normal display during IPL.
Load FIBRE
Normal display during IPL.
Load SCSI
Drive is doing a high speed seek.
Locating
The IPL failed.
Memory Err
The write-protected tape is in the
NTReady F
process of a manual unload.
The non-write-protected tape is in
NTReady U
the process of a manual unload.
95739
Recommended Action
Contact authorized service personnel.
Contact authorized service personnel.
See
"DumpAgain? Condition" on
page
5-8.
Replace the cleaning cartridge.
Optionally move dump/s to the host or
tape. See various dump instructions in
this chapter.
Contact authorized service personnel.
Contact authorized service personnel.
Wait until the IPL automatically
completes.
No user action is necessary.
No user action is necessary.
No user action is necessary.
If another tape also fails load, IPL drive.
If the problem persists, contact
authorized service personnel. If another
tape works, tape is suspect.
No user action is necessary.
No user action is necessary.
No user action is necessary.
Perform an IPL.
If the problem persists, contact
authorized service personnel.
No user action is necessary.
No user action is necessary.
Ninth Edition
Operator Panel Messages
5-5