StorageTek 9840 User's Reference Manual page 133

Hide thumbs Also See for 9840:
Table of Contents

Advertisement

1. Power off the CSL if power is applied
2. Remove all cartridges from the input and output bins.
3. Locate the MUD screw within the CSL input bin (upper-left area).
Note: The CSL MUD screw is located to the right of the feed channel.
FEED
CHANNEL
INPUT
BIN
4. Obtain a long-common 1/8 in. screwdriver and insert it into the MUD slot.
5. Press against the spring-loaded MUD screw until it stops.
WARNING:
Do not turn the screwdriver to the left or counter-clockwise (CCW) when removing a
jammed cartridge.
6. Slowly turn the screwdriver to the right or clockwise (CW) to remove the jammed
cartridge (may take approximately ten turns).
a. Turn the MUD screw until it will not turn any further. This action lowers the reel
motors within the drive.
95739
("Power On/Off CSL" on page
MUD
SCREW
C53620
C53621
Ninth Edition
Jammed Cartridge
6-10).
6-27