Error And Recovery; Operator Indicator; Drive Failure To Load; Figure 6-16. Csl Operator Panel - StorageTek 9840 User's Reference Manual

Hide thumbs Also See for 9840:
Table of Contents

Advertisement

Error and Recovery

Note: Refer to
Errors may be encountered anytime during operation of the CSL. Errors,
recovery, and FSCs are discussed in this chapter.
Note: The 4EXX FSCs are for the CSL only.

Operator Indicator

When the Operator indicator (call out 6) is flashing
detected an operator-intervention condition. Refer to
a description of the Operator indicator.
When the Operator indicator is on constantly, the CSL has detected an error
condition (usually a jammed cartridge or an incorrectly loaded cartridge).

Figure 6-16. CSL Operator Panel

1
10

Drive Failure to Load

Cartridges may be loaded into the CSL incorrectly (priority mount or from the
input bin). Sometimes, cartridges are loaded with the cartridge reels to the left
(Figure 6-17 on page
cartridge into the drive. This type of a load causes an instant CSL failure.
CAUTION:
Never load cartridges with the cartridges reels to the left. Only load
cartridges with the cartridges reels to the right.
95739
Chapter 5, "Drive Errors and Messages,"
2
3
4
service
11
12
13
1. Power Indicator
2. Activity Indicator
3. Clean Indicator
4. Service Indicator
5. IPL Switch
6. Operator Indicator
7. System Indicator
6-22). When this is done, the CSL attempts to load the
Ninth Edition
(Figure
6
5
7
14
8. Automatic Indicator
9. Manual Indicator
10. Unload Switch
11. Menu Switch
12. Select Switch
13. Operator Display
14. Start Switch
15. Autoload Mode Switch

Error and Recovery

for specific drive errors.