3. Pull out on the black lever and slide the carrier from the server system. See letter
"B" in the figure below.

Figure 34. Removing Hot-swap Disk Carrier from the Server System

4. Remove the four screws that attach the plastic retention device or the previously
installed hard drive to the drive carrier. Two screws are at each side of the retention
device or the hard drive. Store the plastic retention device for future use.
5. Remove the hard drive from its wrapper and place it on an antistatic surface.
6. Set any jumpers and/or switches on the drive according to the drive manufacturer's
instructions.
7. With the drive circuit-side down, position the connector end of the drive so that it is
facing the rear of the drive carrier.
8. Align the holes in the drive to the holes in the drive carrier and attach it to the
carrier with the screws that were attached to the plastic retention device.