Clearing The Cmos; Figure 91. Clear Password Jumper - Intel SERVER SYSTEM SR2500AL User Manual

Intel server user manual
Hide thumbs Also See for SERVER SYSTEM SR2500AL:
Table of Contents

Advertisement

2
3
J1D2
4. Wait five seconds.
5. Return the Password Clear jumper to the Password Clear Protect position, covering
pins 1 and 2.
6. Close the server chassis.
7. Reconnect the AC power and power up the server.
8. The password is now cleared and can be reset by going into BIOS setup.

Clearing the CMOS

If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to
be used to reset the configuration RAM.
1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the jumper from the normal operation position, CMOS Clear by BMC, at
pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3.
Intel® Server System SR2500AL User's Guide
BMC Force
Update Mode
Disable
2
Password
Enable
Reset
3
J1D1
2
Clear
CMOS
3
J1D3

Figure 91. Clear Password Jumper