Sign In
Upload
Manuals
Brands
Intel Manuals
Server
SR1500AL - Server System - 0 MB RAM
Intel SR1500AL - Server System - 0 MB RAM Manuals
Manuals and User Guides for Intel SR1500AL - Server System - 0 MB RAM. We have
3
Intel SR1500AL - Server System - 0 MB RAM manuals available for free PDF download: User Manual, Manual, Specification
Intel SR1500AL - Server System - 0 MB RAM User Manual (180 pages)
Server System
Brand:
Intel
| Category:
Server
| Size: 3 MB
Table of Contents
Preface
5
About this Manual
5
Manual Organization
5
Product Contents
5
Intel ® Server System SR1500ALSAS Contents
6
Intel ® Server System SR1500AL Contents
7
Safety Information
9
Important Safety Instructions
9
Consignes de Sécurité
9
Wichtige Sicherheitshinweise
9
Instrucciones de Seguridad Importantes
9
Table of Contents
13
Chapter 1: Server System References
23
Table 1. Server System References
23
Chapter 2: Server System Features
25
Figure 1. Intel ® Integrated Server System SR1500AL
25
Table 2. Intel ® Server System SR1500AL Feature Summary
26
Chassis Component Identification
28
Internal Components
28
Figure 2. Chassiscomponents
28
Figure 3. Server Board Connector and Component Locations
29
Configuration Jumpers
30
Figure 4. BIOS Select Jumper
30
Figure 5. Recovery Jumpers
31
Figure 6. Light Guided Diagnostic Leds
32
Figure 7. Back Panel Connectors
33
Table 3. NIC LED Descriptions
33
Figure 8. Active Backplane Components
34
RAID Support
35
Figure 9. Passive Backplane Components
35
Standard Control Panel
36
Figure 10. Standard Control Panel
37
Intel ® Local Control Panel
37
Bezels
38
Figure 11. Intel ® Local Control Panel
38
Figure 12. Server System Back
39
Rear of Server System
39
Peripheral Devices
40
Hard Disk Drives
40
Figure 13. Optional Peripherals
40
Slimline Optical Drive Carrier
41
Advanced Management Options
41
Intel® Remote Management Module
41
Rack-Mounted Systems
41
Chapter 3: Hardware Installations and Upgrades
43
Before You Begin
43
Tools and Supplies Needed
43
System References
43
Removing and Installing from a Rack
43
Fixed Bracket Rack Mount Removal
43
Fixed Bracket Rack Mount Installation
44
Basic Rail Rack Mount Removal
45
Basic Rail Rack Mount Installation
45
Tool-Less Rail Rack Mount Servicing
46
Removing and Installing the Front Bezel
46
Figure 14. Front View with Bezel Supporting the Standard Control Panel
46
Figure 15. Front View with Bezel Supporting the Intel
46
Removing the Front Bezel
47
Figure 16. Removing the Front Bezel
47
Installing the Front Bezel
48
Removing and Installing the System Cover
48
Removing the System Cover
48
Figure 17. Installing the Front Bezel
48
Installing the System Cover
49
Figure 18. Removing the Server System Cover
49
Removing and Installing the Processor Air Duct
50
Removing the Processor Air Duct
50
Figure 19. Installing the Server System Cover
50
Figure 20. Removing the Processor Air Duct
51
Installing the Processor Air Duct
52
Figure 21. Removing the Processor 2 Air Dam (Optional - Only if Two Processors Are Installed)
52
Installing and Removing Memory
53
Installing Dimms
53
Figure 22. Installing the Processor Air Duct
53
Figure 23. Installing the Memory
54
Removing Dimms
55
Installing the Processor
55
Figure 24. Lifting the Processor Socket Handle
56
Figure 25. Installing the Processor
56
Installing the Heat Sink(S)
57
Figure 26. Removing the Socket Cover
57
Removing a Processor
58
Figure 27. Installing the Heat Sink (2U Passive Heat Sink Shown)
58
Removing and Installing the Small Air Baffle
59
Removing the Small Air Baffle
60
Installing the Small Air Baffle
60
Figure 28. Removing the Small Air Baffle
60
Installing and Removing a Hot-Swap Hard Drive
61
Installing a SAS or SATA Hot-Swap Hard Disk Drive
61
Figure 29. Installing the Small Air Baffle
61
Figure 30. Removing Hot-Swap Disk Carrier from the Server System
62
Figure 31. Removing Retention Device from Drive Carrier
62
Figure 32. Installing Hard Drive into Carrier
63
Figure 33. Install Drive Assemby into the Server System
63
Removing a SAS or SATA Hot-Swap Hard Disk Drive
64
Installing or Removing a Slimline Optical Drive or Internal USB Floppy
64
Installing a Slimline Optical Drive or Internal USB Floppy
65
Figure 34. Installing an Optical Drive into the Drive Tray
65
Removing a Slimline Optical Drive or Internal USB Floppy
66
Figure 35. Installing an Optical Drive Assembly into the Server System
66
Figure 36. Removing the Slimline Optical Drive Assembly from the Server System
67
Filling Empty Server System Bays
68
Figure 37. Removing the Slimline Optical Drive from the Tray
68
Installing and Removing the PCI Riser Assembly
69
Removing the PCI Riser Assembly
69
Figure 38. Removing PCI Riser Assembly from the Server System
69
Installing the PCI Riser Assembly
70
Figure 39. Installing PCI Riser Assembly into the Server System
70
Replacing a PCI Riser Card
71
Removing the PCI Express* Riser Card
71
Figure 40. Removing the PCI Express* Riser Card from the Server System
72
Installing the PCI-X* Riser Card
73
Figure 41. Installing the PCI-X* Riser Card into the Server System
73
Installing and Removing a PCI Add-In Card
74
Installing a PCI Add-In Card
74
Figure 42. I Installing a Full Height Add-In Card
74
Removing a PCI Add-In Card
75
Figure 43. Removing a Full Height Add-In Card
75
Installing and Removing the I/O Expansion Module(S)
76
Installing the I/O Expansion Module(S)
76
Figure 44. Installing the I/O Expansion Module to the Server Board
76
Removing the I/O Expansion Module(S)
77
Figure 45. Removing the I/O Expansion Module(S) from the Server Board
77
Rmm Nic
78
Installing the Intel ® RMM and Intel ® RMM NIC
78
Figure 46. Installing the Intel ® RMM and the Intel ® RMM NIC Module to the Server System
78
Removing the Intel ® RMM and Intel ® RMM NIC
79
Replacing the Backplane Board
80
Removing the Backplane Board
80
Figure 48. Removing the Bridge Board from the Server System
80
Installing the Backplane Board
81
Figure 49. Removing the Backplane from the Server System
81
Figure 50. Installing the Backplane into the Server System
82
Figure 51. Installing the Bridge Board into the Server System
83
Installing and Removing the Server Board
84
Installing the Server Board
84
Figure 52. Installing the Server Board
84
Removing the Server Board
85
Figure 53. Removing the Server Board
85
Replacing the Backup Battery
86
Figure 54. Replacing the Backup Battery
87
Replacing the Power Supply
88
Figure 55. Removing Power Supply Module from the Server System
88
Figure 56. Installing Power Supply Module into the Server System
88
Replacing the Control Panel
89
Figure 57. Removing the Intel ® Local Control Panel Module
90
Figure 58. Installing Control Panel Module into the Server System
90
Replacing a System Fan
91
Figure 59. I Removing a Fan from the Fan Module
91
Installing and Removing the Rack Handles
92
Installing the Rack Handles
92
Figure 60. I Installing a Fan into the Fan Module
92
Removing the Rack Handles
93
Figure 61. I Installing the Rack Handle
93
Figure 62. I Removing the Rack Handle
94
Chapter 4: Server Utilities
95
Using the BIOS Setup Utility
95
Starting Setup
95
If You Cannot Access Setup
95
Setup Menus
95
Table 4. Setup Menu Key Use
96
Upgrading the BIOS
97
Preparing for the Upgrade
97
Upgrading the BIOS
98
Clearing the Password
98
Clearing the CMOS
99
Figure 63. Clear Password Jumper
99
Figure 64. Clear CMOS Jumper
100
Appendix A: Technical Reference
101
Cable Routing
101
Figure 65. Cable Routing
101
SATA Connections
102
Figure 66. Connecting SATA Cables
102
600W Single Power Supply Input Voltages
103
Figure 67. Cabling Around the Small Air Baffle
103
600W Single Power Supply Output Voltages
104
Table 5. Power Supply Output Capability
104
System Environmental Specifications
105
Table 6. System Environmental Specifications
105
Appendix B: Troubleshooting
107
Resetting the System
107
Table 7. Resetting the System
107
Problems Following Initial System Installation
108
First Steps Checklist
108
Hardware Diagnostic Testing
109
Verifying Proper Operation of Key System Lights
109
Confirming Loading of the Operating System
109
Specific Problems and Corrective Actions
110
Power Light Does Not Light
110
No Characters Appear on Screen
111
Characters Are Distorted or Incorrect
111
System Cooling Fans Do Not Rotate Properly
112
Drive Activity Light Does Not Light
112
CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light
112
Cannot Connect to a Server
113
Problems with Network
113
System Boots When Installing PCI Card
114
Intel ® Server System SR1500AL User's Guide
114
Problems with Newly Installed Application Software
114
Problems with Application Software that Ran Correctly Earlier
114
Devices Are Not Recognized under Device Manager (Microsoft* Windows* Operating System)
115
Hard Drive(S) Are Not Recognized
115
Bootable CD-ROM Disk Is Not Detected
115
LED Information
116
BIOS POST Beep Codes
116
Table 8. LED Information
116
Table 9. POST Error Beep Codes
116
Table 10. Error Beep Codes Generated by Intel
117
Appendix C: Intel ® Server Issue Report Form
119
Operating System Information
120
Appendix D: LED Decoder
123
Table 11. POST Progress Code LED Example
123
Figure 68. Diagnostic LED Placement Diagram
124
Table 12. Diagnostic LED POST Code Decoder
124
Appendix E: Getting Help
129
World Wide Web
129
Telephone
129
Latin America
130
Appendix F: Regulatory and Compliance Information
133
Product Regulatory Compliance
133
Product Safety Compliance
133
Product EMC Compliance - Class a Compliance
134
Certifications / Registrations / Declarations
135
Product Regulatory Compliance Markings
135
Table 13. Product Regulatory Compliance Markings
135
Electromagnetic Compatibility Notices
137
FCC Verification Statement (USA)
137
Industry Canada (ICES-003)
138
Europe (CE Declaration of Conformity)
138
VCCI (Japan)
138
BSMI (Taiwan)
138
Korean Compliance (RRL)
139
CNCA (CCC-China)
139
Regulated Specified Components
139
Restriction of Hazardous Substances (Rohs) Compliance
140
End-Of-Life / Product Recycling
140
Appendix G: Warranty
141
Limited Warranty for Intel® Chassis Subassembly Products
141
Warranty Limitations and Exclusions
142
Limitations of Liability
142
How to Obtain Warranty Service
142
Telephone Support
143
Returning a Defective Product
143
Appendix H: Installation/Assembly Safety Instructions
145
English
145
Deutsch
147
Français
149
Español
151
Chinese
153
Italiano
154
Appendix I: Safety Information
157
English
157
Server Safety Information
157
Safety Warnings and Cautions
157
Intended Application Uses
158
Site Selection
158
Equipment Handling Practices
158
Power and Electrical Warnings
159
System Access Warnings
160
Rack Mount Warnings
160
Electrostatic Discharge (ESD)
161
Other Hazards
161
Deutsch
162
Sicherheitshinweise für den Server
162
Sicherheitshinweise und Vorsichtsmaßnahmen
162
Zielbenutzer der Anwendung
163
Standortauswahl
163
Handhabung von Geräten
163
Warnungen zu Netzspannung und Elektrizität
164
Warnhinweise für den Systemzugang
165
Warnhinweise für Racks
165
Elektrostatische Entladungen (ESD)
166
Andere Gefahren
166
Français
167
Consignes de Securite Sur Le Serveur
167
Séurité: Avertissements Et Mises en Garde
167
Domaines D'utilisation Prévus
168
Sélection D'un Emplacement
168
Pratiques de Manipulation de L'équipement
169
Alimentation Et Avertissements en Matiére D'électricité
169
Avertissements Sur Le Cordon D'alimentation
170
Avertissements Sur L'accés Au Systéme
170
Avertissements Sur Le Montage en Rack
171
Décharges Électrostatiques (ESD)
172
Autres Risques
172
Périphériques Laser
173
Español
173
Información de Seguridad del Servidor
173
Advertencias y Precauciones sobre Seguridad
173
Aplicaciones y Usos Previstos
174
Seleccién de la Ubicación
174
Manipulacién del Equipo
175
Advertencias de Alimentacién y Eléctricas
175
Advertencias sobre el Cable de Alimentación
175
Advertencias el Acceso al Sistema
176
Advertencias sobre el Montaje en Bastidor
177
Otros Riesgos
178
Advertisement
Intel SR1500AL - Server System - 0 MB RAM Manual (87 pages)
Server Chassis/Server System
Brand:
Intel
| Category:
Server
| Size: 1 MB
Table of Contents
Table of Contents
4
1 Product Overview
13
Chassis Views
13
Figure 1. Front View with Bezel - Showing the Intel Local Control Panel Option
13
Figure 2. Front View Without Bezel - Showing the Standard Control Panel Option
13
Figure 3. Rear Chassis View
13
Chassis Dimensions
14
System Components
14
Figure 4. Major Chassis Components
14
Table 1. Chassis Dimensions
14
System Boards
15
Figure 5. Back Panel Feature Overview
15
Control Panel Options
16
Figure 6. Control Panel Modules
16
Figure 7. Standard Control Panel Overview
17
Figure 8. LCD Control Panel Overview
17
Hard Drive and Peripheral Bays
18
Power Sub-System
18
Figure 9. Drive Bay Overview
18
System Cooling
19
Chassis Security
19
1.10 Rack and Cabinet Mounting Options
19
1.11 Front Bezels
20
Figure 10. Optional Front Bezel
20
Figure 11. Front Bezel Options
20
2 Power Sub-System
21
Mechanical Overview
21
Figure 12. Power Supply Mechanical Drawing
21
2.2 Output Connectors
22
Table 2. Cable Harness Definition
22
Table 3. P1 - Main Power Connector Pin-Out
22
2.3 Efficiency
23
Table 4. P2 - Processor Power Connector Pin-Out
23
Table 5. P3 - Back Plane Power Connector Pin-Out
23
Table 6. P4 - Baseboard Signal Connector Pin-Out
23
Table 7. Power Supply Efficiency
23
AC Input Voltage Requirement
24
Protection Circuits
24
Over-Current Protection (OCP)
24
Table 8. AC Input Rating
24
Table 9. Over-Current Protection (OCP)
24
Over-Voltage Protection (OVP)
25
Over-Temperature Protection (OTP)
25
Power Supply Status LED
25
Table 10. Over-Voltage Protection (OVP) Limits
25
Table 11. LED Indicators
25
AC Power Cord Specification Requirements
26
3 Cooling Sub-System
27
Five-Fan Module
27
Figure 13. Fan Module Assembly
27
Table 12 Non-Redundant Cooling Zones
27
Power Supply Fans
28
CPU Air Duct and Air Baffle
28
Table 13. Individual Fan Assembly Pin-Out
28
Figure 14. Air Baffle
29
Figure 15. CPU Air Duct
29
Drive Bay Population
30
Figure 16. Hard Drive Carrier
30
4 Platform Control
31
Overview
31
5 Peripheral and Hard Drive Support
32
Optical and Floppy Drive Support
32
USB Floppy Drive Support
32
Figure 17. Intel
32
Table 14. 4-Pin USB Floppy Connector Pin-Out
32
Optical Drive Support
33
Figure 18. View of Slimline Drive Bay
33
Table 15. 44-Pin Internal CD-ROM Connector Pin-Out
33
Hard Disk Drive Support
34
Hot-Swap Hard Disk Drive Trays
34
Drive Blanks
34
Figure 19. Hard Drive Tray Assembly
34
Hot-Swap Backplane Support
35
Figure 20. Drive Tray with Drive Blank
35
Feature Set
36
Figure 21. Hot-Swap Passive SAS/SATA Backplane Layout
37
Figure 22. Active SAS Backplane Layout
38
Figure 23. Hot-Swap Passive SAS/SATA Backplane Functional Diagram
39
Figure 24. Hot-Swap Active SAS Backplane Functional Diagram
39
LSI* SAS1064E 3.0 Gbit/S Serial Attached SCSI Controller
40
Vitesse* VSC410 Enclosure Management Controller
40
LED Support
42
Table 16. LED Function
42
Table 17. Hard Drive Activity LED Functionality
42
Backplane Connector Definitions
43
Figure 25. Bridge Board Layout
43
Table 18. Backplane Power Connector Pin-Out (J1B1)
43
Table 19. Bridge Board Connector Pin-Out (J5A1)
44
Table 20. Backplane Control Panel Connector Pin-Out (J9C1)
45
Table 21. 1X10 Pin Control Panel USB Connector Pin-Out (J6B1)
46
Table 22. SAS/SATA Hard Drive Connector Pin-Outs (J8N1, J6N1, J3N1)
46
Table 23. SATA/SAS Drive Control Connector Pin-Out (J3C1, J4B2, J4A1)
47
Table 24. 4-Pin Floppy Connector Pin-Out (J2B1)
47
Table 25. System Fan Connector Pin-Outs
48
Table 26. IPMB Connector Pin-Out (J1C1)
49
Table 27. Add-In Card Connector Pin-Out (J4B3 - Passive Only)
49
6 Standard Control Panel
50
Figure 26. Standard Control Panel Assembly Module
50
Control Panel Buttons
51
Control Panel LED Indicators
51
Figure 27. Control Panel Buttons
51
Figure 28. Control Panel LED Indicators
51
Table 28. Control Button and Intrusion Switch Functions
51
Power / Sleep LED
52
Table 29. Control Panel LED Functions
52
Table 30. SSI Power LED Operation
52
System Status LED
53
Table 31. Control Panel LED Operation
53
Drive Activity LED
54
System Identification LED
54
Control Panel Connectors
54
Table 32. External USB Connectors (J1B1)
54
Table 33. Video Connector (J1A1)
54
7 Intel Local Control Panel
56
Figure 29. Intel
56
Figure 30. Intel
56
LED Functionality
57
Power / Sleep LED
57
Table 34. Control Panel LED Functions
57
Table 35. SSI Power LED Operation
57
System Status LED
58
Table 36. Control Panel LED Operation
58
Drive Activity LED
59
System Identification LED
59
8 PCI Riser Cards and Assembly
60
Figure 31. PCI Riser Card Assembly - FH View
60
Riser Card Options
61
Figure 32. PCI Riser Card Assembly - LP View
61
Figure 33. 1U Low Profile PCI-X* Riser Card Mechanical Drawing
62
Figure 34. 1U Full Height PCI-X* Riser Card Mechanical Drawing
63
Figure 35. 1U Full Height PCI Express* Riser Card Mechanical Drawing
64
9 Supported Intel Server Boards
65
Intel ® Server Board S5000PAL
65
Processor Support
68
10 Environmental and Regulatory Specifications
69
10.1 System Level Environmental Limits
69
10.2 Serviceability and Availability
69
10.3 Replacing the Back up Battery
70
10.4 Product Regulatory Compliance
71
10.5 Use of Specified Regulated Components
71
10.6 Electromagnetic Compatibility Notices
73
Usa
73
FCC Verification Statement
74
ICES-003 (Canada)
74
Europe (CE Declaration of Conformity)
74
Japan EMC Compatibility
74
BSMI (Taiwan)
75
RRL (Korea)
75
CNCA (CCC-China)
75
10.7 Product Ecology Compliance
76
10.8 Other Markings
78
Appendix A: Integration and Usage Tips
80
Appendix B: POST Code Diagnostic LED Decoder
81
Appendix C: POST Error Beep Codes
85
Glossary
86
Reference Documents
87
Intel SR1500AL - Server System - 0 MB RAM Specification (42 pages)
Specification Update
Brand:
Intel
| Category:
Motherboard
| Size: 0 MB
Table of Contents
Revision History
2
Table of Contents
4
Preface
7
Summary Tables of Changes
8
Errata
11
IPMI over Serial Direct Connect Not Supported
11
Serial over LAN and IPMI over LAN Connections May Terminate Unexpectedly under Certain Conditions
11
Intermittent Beep Code 1-5-2-1 When Booting with Two Processors
11
Power Supply Population Errors May Not Display in the SEL
11
Fan 5 May Report a Reading of 0 RPM after the BMC Is Updated
12
The BMC May Not Respond to the IPMI Command, Send Message Sent Via LAN
12
Fans May Take a Long Time to Slow down after Fan Boosting
13
System Requires ~35 Seconds after AC Power Is Applied before the Power Button Responds
13
SEL Events for Hot-Swap Controller (HSC) May Appear after a DC Cycle
13
Fans May Run Faster than Expected after Exiting BIOS Setup
13
System Fault LED May Report Incorrect Status for some Events
14
Fan Removal Does Not Generate a SEL Event
14
Power Supply Redundancy State Is Misleading When Only One Power Supply Is Installed
15
Hot-Swap Controller (HSC) and Local Control Panel (LCP) Updates May Take a Long Time
15
Console Redirection Baud Rate Setting Auto Changing to 19.2K with Serial over LAN (SOL) Active
15
Serial over LAN (SOL) Unable to Redirect DOS Output
16
Password on Boot Not Supported
16
Intel® Embedded Server RAID Technology II Option Is Not Enabled in Initial BIOS
16
Release
16
HSC and BMC Versions Intermittently Not Seen in BIOS Setup
16
Intel® Server Boards S5000PAL/S5000XAL and Intel® Server System SR1500AL
17
Testing
17
Show a "Changes in Hardware or Drivers Detected" Error Message During WHQL ACPI Stress Testing
17
POST Leds Do Not Turn off after Operating System Loads
17
Checkup7.Exe (Microcode Update Utility) Is Not Storing Microcode in BIOS
18
Intel® RAID Controller SRCSAS144E Causes Systems to Reset Multiple Times before Completing POST
18
Change Logo Utility Does Not Save Modified BIOS Capsule Files with Correct Extension
19
PS/2 Keyboards and Mice May Stop Functioning after Red Hat* Enterprise Linux Is Installed
19
Failures Seen Installing to a SATA Drive When SATA Is Set to "Legacy" in the BIOS
20
Setup
20
System Hangs after Disabling On-Board Video in the BIOS Setup
20
The SMBIOS Entry Point May Not be Visible under Certain Hardware Configurations14
20
Suse* Linux Enterprise Server May Not Install Successfully with Intel® Embedded Server RAID Technology II Enabled
21
Red Hat* Enterprise Linux 4 and BIOS Setup Display a Different L2 Cache Size for the Quad-Core Intel® Xeon® Processor 5300 Series
22
Change Logo Utility Causes BIOS Corruption
22
Microsoft Windows System Event Viewer* May Record Error Event with ID 11
22
After the System Reboots, the POST Screen May Generate "NMI Has Been Received - System Halted" Message
23
Intel® RAID Web Console 2 Utility Displays "Unexpected Sensor" Warning Message in Microsoft Windows* Operating System
23
Random Drives May Go Offline When a Sixth Drive Is Installed and Intel® Embedded Server RAID Technology II Is Enabled in the Intel® Server System SR2500ALBRP
24
Dual Gigabit Expansion Module May Not Properly Reset
24
SAS Drive in a ROMB RAID 5 May Drop Offline During a Reboot in the Intel® Server System SR2500PALLX
25
Intel® Server System SR2500ALLX Sixth Hard Drive Filler Panel Is Difficult to
25
Remove
25
Suse* Linux Enterprise Server Unable to Boot after Basic Installation
26
Drives May Not be Detected or May Go Offline in the Intel® Server System SR2500ALBRP When Operating at SATA 3Gb/S Data Rate
26
New Versions of BMC Firmware with Previous Versions of BIOS Cause System POST Failure
27
Intel® Server System SR2500ALLX May Operate Louder than Expected
27
Red Hat* Enterprise Linux May Report the Wrong Processor Speed
27
The Suse* Linux Enterprise Server 10 Driver for SAS HW RAID Causes Unwanted Error Logs During Installation
27
IERR or Thermal Trip Event Reported in System Event Log (SEL) after System Power on
28
USB Device Generates "The Following Boot-Start or System-Start Driver(S) Failed to Load: I8042Prt" Error Message in Microsoft Windows* Operating Systems
29
Microsoft Windows* and Intel® RAID Web Console II Report an Error When the ASR2500SATAPE Kit Is Used
29
System May Log Ierrs When Running Certain Red Hat* Enterprise Linux Versions on the Intel® Server Board S5000PAL with Video Driver Ati_Drv.o 6.5.6
29
Microsoft Windows* Operating Systems Installed Without a Service Pack will Display Blue Screen with BIOS 79 and 81
30
Sluggish System Performance May be Experienced with BMC 60
31
Downgrading the Firmware of the Integrated RAID (ROMB), Intel® Embedded Server RAID Technology II, or SAS May Cause System Damage
31
In the Intel® Server Systems SR2500ALLX and SR1550ALSAS, Flashing of SAS
31
During SAS Controller Scanning
31
Firmware 1.22 and SAS BIOS 06.16.00 Makes Hard Drive #1 (Upper Left Drive Tray) Undetected During SAS Controller Scanning
31
Microsoft Windows 2003 R2 SP2* May Display Blue Screen During an Operating System Boot or Shutdown with a Specific Version of Intel I/OAT Driver
32
Server System Event Log (SEL) Time May be One Day Later than BIOS Time after Entering Year 2008
33
Performance Power Management Error in Microsoft Windows Server 2008
33
Midplane2 Hardware RAID Produces Unexpected Beep Sounds During System POST
34
Platform Confidence Test (PCT) Fails with BIOS 89/91 on Intel® Server Board S5000PAL/S5000XAL
34
USB Mouse May Hang in BIOS 94 RAID Console
34
PCI IBIST Error with BIOS 84
35
System May Hang During Login or Shutdown
35
Hard Disks Are Difficult to Install in Intel® Server System SR2500AL and Intel® Server Chassis SR2500
35
System will Not Skip CD/DVD Drive with BIOS Revision R0098 When RMM2 Installed
36
Please Use AXXMINIDIMM512 as the Replacement Solution for AXXMINIDIMM Which Is Eoled
37
Minus "Year" Number to Go Past "2000" at BIOS "System Date" Set up Interface will Cause the Server System to Hang
37
Please Do Not Downgrade BIOS from Factory Shipped BIOS 101 to any Previous Version
37
The Serial Port Console Redirection Displays the Adaptec® 5805 RAID
38
Documentation Changes
39
The SMBUS Block Diagram (Figure #16) Provided in Rev. 1.1 of the Intel Server Board S5000PAL/S5000XAL TPS Requires Changes to Accurately Reflect Production Hardware Design
39
The Power Block Diagram (Figure #25) as Provided in Rev. 1.1 of the Intel Server Board S5000PAL/S5000XAL TPS Does Not Reflect the Final, Production-Level Baseboard Design
40
SAS/SAS RAID Midplane Board (Figure #22) as Provided in Rev.1.0 of the Intel
41
Front Panel Pin-Out in the Intel
42
Advertisement
Advertisement
Related Products
Intel SR1500ALSAS - Server System - 0 MB RAM
Intel SR1500ALRNA - Server System - 0 MB RAM
Intel SR1530AHNA
Intel SR1550ALSASRNA - Server System - 0 MB RAM
Intel SR1520ML - Server System - 0 MB RAM
Intel SR1530HCL - Server System - 0 MB RAM
Intel SR1530HCLSRNA - Server System - 0 MB RAM
Intel SR1530CL - Server System - 0 MB RAM
Intel SR1550AL - Server System - 0 MB RAM
Intel SR1530HCLR
Intel Categories
Motherboard
Computer Hardware
Server
Desktop
Server Board
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL