Flash Off Time

This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
3. Go to
4. Scan the bar code: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
This completes the procedure. See
Table 43. Flash Off Time Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 100 (and pad with
2
leading zeroes to yield two
digits)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
276
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
page 98
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter
Programming Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
Mode.
500ms
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT FLASH OFF TIME SETTING
'0' and '5'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Table 43
for some examples of how to set this feature.
EXAMPLES
1,000ms (1 sec.)
5200ms (5.2 sec.)
10
'1' and '0'
Keypad, that represent
9,900ms (9.9 sec.)
52
99
'5' and '2'
'9' and '9'
Gryphon™ I GD44XX/GBT4400