Flash On Time; Flash Off Time - Datalogic Gryphon I GM440 Series Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for Gryphon I GM440 Series:
Table of Contents

Advertisement

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments. See
information on setting this feature.
$CSNFN
Select Flash ON Time Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.

Flash Off Time

This feature specifies the OFF time for the indicator LED while in Flash
Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 sec-
onds), in 100 millisecond increments. See
detailed information on setting this feature.
$CSNFF
Select Flash OFF Time Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
Product Reference Guide
10 = Flash is ON for 1 Second
DEFAULT
06 = Flash is OFF for 600ms
DEFAULT
Enter/Exit Programming Mode
page 298
in "References" for detailed
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
your desired character(s). End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
page 299
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
your desired character(s). End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
representing
in "References" for
representing
107

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents