Flash On Time; Flash Off Time - Datalogic Gryphon Series Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for Gryphon Series:
Table of Contents

Advertisement

Reading Parameters

Flash On Time

This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See
page 281
$CSNFN
Select Flash ON Time Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again at
the beginning.

Flash Off Time

This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable
range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See
page 282
$CSNFF
Select Flash OFF Time Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again at
the beginning.
Product Reference Guide
in "References" for detailed information on setting this feature.
DEFAULT
in "References" for detailed information on setting this feature.
DEFAULT
Enter/Exit Programming Mode
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
desired character(s). End by scanning the ENTER/EXIT
bar code again.
~
10 = Flash is ON for 1 Second
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
desired character(s). End by scanning the ENTER/EXIT
bar code again.
~
06 = Flash is OFF for 600ms
representing your
CANCEL
representing your
CANCEL
103

Advertisement

Table of Contents
loading