Docking Beep; Leash Alarm - Datalogic Gryphon I GBT4400 Product Reference Manual

General purpose handheld area imager bar code reader
Hide thumbs Also See for Gryphon I GBT4400:
Table of Contents

Advertisement

Enter/Exit Programming Mode

Docking Beep

Enables/disables a beep indication when the handheld is placed in the Base Station.
$CBTCB00(CR)
Docking Beep = Disable
$CBTCB01(CR)
DEFAULT
Docking Beep = Enable

Leash Alarm

This setting specifies the number of seconds to sound the Leash Mode beeps (three per second)
when the handheld goes out of range. This is especially useful in instances where the reader
might inadvertently have been placed in a bag or cart.
For this mode to be effective, the reader must be linked to the Base Station and
"LED and
Beeper Indicators" on page 88
must be disabled. If the reader is asleep or disconnected from the
Base Station, there is no way for it to know where it is relative to the Base Station because
communication is not active between the devices.
$CBTLB00(CR)
DEFAULT
Leash Alarm = Disabled
$CBTLB01(CR)
Leash Alarm = 1 Second
$CBTLB02(CR)
Leash Alarm = 2 Seconds
Product Reference Guide
233

Advertisement

Table of Contents
loading

Table of Contents