Enter/Exit Programming Mode
ACK NAK Error Handling
This feature specifies the method the reader uses to handle receive errors detected while waiting
for an ACK character from the host.
DEFAULT
$CR2EH01(CR)
ACK NAK Error Handling = Process Error as Valid ACK
Character
Indicate Transmission Failure
This option enables/disables the reader's ability to sound an error beep to indicate a
transmission failure while in ACK/NAK mode
$CR2TF01(CR)
Indicate Transmission Failure = Enable Indication
50
$CR2EH00(CR)
ACK NAK Error Handling = Ignore Errors Detected
$CR2EH02(CR)
ACK NAK Error Handling = Process Error as
Valid NAK Character
.
$CR2TF00(CR)
Indicate Transmission Failure = Disable Indication
DEFAULT
Gryphon™ I GD44XX/GBT4400