Horizontal Min. / Max. Venting Illustrations - kozy heat PRINCETON RPC-36 Installation And Optimization Manual

Direct vent
Table of Contents

Advertisement

HORIZONTAL TERMINATIONS
MINIMUM HORIZONTAL VENTING
NOTE: Horizontal sections re-
quire 1/4" (6 mm) rise for every
12" (305 mm) of travel.
CAUTION: This gas appliance must
not be connected to or joined with
any other chimney flue serving
another appliance.
IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD MUST BE INSTALLED WHEN USING A 45-DEGREE ELBOW DIRECTLY
OFF FIREPLACE TO HORIZONTALLY POSITION THE VENT SYSTEM. EXCEPTION: CORNER INSTALLATIONS
THE KOZY HEAT WALL PASS-THRU, PART #800-WPT (4-1/2" (114 mm) - 6-1/2" (165 mm) WALL THICKNESS) OR #800-WPT2 (6-1/2" (165
mm) - 12-1/2" (318 mm) WALL THICKNESS), MUST BE USED ON ALL HORIZONTAL VENT RUNS.
MAXIMUM HORIZONTAL VENTING: OPTION #1
Horizontal vent heat shield not shown for clarity purposes only.
MAXIMUM HORIZONTAL VENTING: OPTION #2
6" (152 mm) VENT
PIPE SECTION
NOTE: Page 25 has information on restrictor installation in conjunction with venting installation. Page 50 has information on restrictor
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
VENTING
TERMINATION CAP
5 ft.
(1.52 m)
45° ELBOW
TERMINATION CAP
10 ft.
(3.05 m)
45° ELBOW
TERMINATION CAP
(Horizontal)
6" (152 mm) VENT
PIPE SECTION
PAGE 22
HORIZONTAL VENT
HEAT SHIELD
45° ELBOW