Horizontal Min. / Max. Venting Illustrations - kozy heat Dassel DSL-36 Installation And Operation Manual

Table of Contents

Advertisement

Page 22 has information on restrictor installation in conjunction with venting installation. Page 49 has information on restrictor
NOTE
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
MIN. / MAX. HORIZONTAL VENTING (5"x 8")
HORIZONTAL VENT HEAT SHIELD
Figure 19a
The horizontal vent heat shield must be installed when using a 90-degree elbow to horizontally position the vent system.
Kozy Heat Wall Pass-thru, #800-WPT (4-1/2" (114mm) - 6-1/2" (165mm) wall thickness),
IMPORTANT
or #800-WPT2 (6-1/2" (165mm)-12-1/2" (318mm) wall thickness) must be used on all horizontal vent runs if using 5" x 8" venting.
If using Dura-Vent 8" x 6-5/8" Decreaser, follow vent pipe manufacturer‟s installation instructions for their wall thimble.
MIN. / IMAX HORIZONTAL VENTING (8" x 6-5/8" DECREASER)
90° ELBOW
8" x 6-5/8" DECREASER
2ft. (610mm)
Figure 19b
VENTING
MINIMUM: 6in. (152mm)
MAXIMUM: 25ft. (7.62m); 30ft. (9.14m) when using stainless
TERMINATION CAP
90° ELBOW
MINIMUM: 6in. (152mm)
MAXIMUM: 25ft. (7.62m); 30ft. (9.14m) when using stainless
TERMINATION CAP
19
steel pipe for entire length of termination.
steel pipe for entire length of termination.