Horizontal Min. / Max. Venting Illustrations - kozy heat Princeton PRC-36 Installation And Operation Manual

Direct vent fireplace
Hide thumbs Also See for Princeton PRC-36:
Table of Contents

Advertisement

HORIZONTAL TERMINATIONS
NOTE: Horizontal sections require 1/4" (6 mm) rise for every 12" (305 mm) of travel.
NOTE: Page 27 has information on restrictor installation in conjunction with venting installation. Page 65 has information on restrictor
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.
Exception: corner installations
Kozy Heat Wall Pass-thru, #800-WPT (4-1/2" (114 mm) - 6-1/2" (165 mm) wall thickness) or #800-WPT2 (6-1/2" (165 mm) - 12-1/2" (318 mm) wall
thickness), must be used on all horizontal vent runs.
MINIMUM HORIZONTAL VENTING
MAXIMUM HORIZONTAL VENTING: OPTION #1
MAXIMUM HORIZONTAL VENTING: OPTION #2
VENTING
TERMINATION CAP
45° ELBOW
Horizontal vent heat shield not shown for clarity purposes only.
45° ELBOW
6" (152 mm) VENT
PIPE SECTION
(Horizontal)
HORIZONTAL VENT
45° ELBOW
6" (152 mm) VENT
PIPE SECTION
5 ft.
(1.52 m)
TERMINATION CAP
10 ft.
(3.05 m)
TERMINATION CAP
PAGE 24
HEAT SHIELD