Horizontal Min. / Max. Venting Illustrations - kozy heat Minnetonka-MTK 55345 Installation And Operation Manual

Direct vent fireplace
Hide thumbs Also See for Minnetonka-MTK 55345:
Table of Contents

Advertisement

HORIZONTAL TERMINATIONS
NOTE: Horizontal sections require 1/4" (6 mm) rise for every 12" (305 mm) of travel.
NOTE: Page 22 has information on restrictor installation in conjunction with venting installation. Page 50 has information on restrictor
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
IMPORTANT: The horizontal vent heat shield must be installed when using a 45-degree elbow to horizontally position the vent system.
Exception: corner installations
Kozy Heat Wall Pass-thru, #800-WPT (4-1/2" (114 mm) - 6-1/2" (165 mm) wall thickness) or #800-WPT2 (6-1/2" (165 mm) - 12-1/2" (318 mm) wall
thickness), must be used on all horizontal vent runs.
Minimum: 6" (152 mm)
Maximum: 10ft. (3.05m)
Termination Cap
Figure 20a
TYPICAL CORNER INSTALLATION
45° elbow + 90˚ elbow + horizontal pipe + termination cap.
Vent Opening Dimensions: Refer to vent pipe manufacturer's instructions.
VENTING
Horizontal Vent Heat
Shield
45° Elbow
PAGE 20
Termination Cap
Pipe
90° Elbow
45° Elbow
Figure 20b