HORIZONTAL TERMINATIONS
90° ELBOW
HORIZONTAL VENT
HEAT SHIELD
CAUTION: This gas
appliance must not be
connected to or joined
with any other chimney
flue serving another
appliance.
HORIZONTAL VENT
HEAT SHIELD
90° ELBOW
NOTE: Horizontal sections require 1/4" (6 mm)
rise for every 12" (305 mm) of travel.
VENTING
IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU
(#800-WPT) MUST BE USED ON ALL HORIZONTAL VENT
RUNS USING 5" x 8" VENTING. FOLLOW INSTRUCTIONS ON
PAGE 23 OF THIS INSTALLATION MANUAL.
MAXIMUM HORIZONTAL VENTING
25 ft. (7.62 m) maximum, or 30 ft (9.14 m) maximum when
30 ft.*
using stainless steel pipe for the entire length of termination.
(9.14 m)*
MAXIMUM HORIZONTAL VENTING
5" X 8"
PAGE 24
MINIMUM HORIZONTAL
TERMINATION CAP
6" (152 mm) VENT
PIPE SECTION
IMPORTANT:
HEAT SHIELD INCLUDED WITH THIS
FIREPLACE MUST BE INSTALLED
WHEN USING A 90-DEGREE ELBOW
DIRECTLY OFF THE TOP OF UNIT TO
HORIZONTALLY POSITION THE VENT
SYSTEM. THIS INCLUDES ANY
CORNER INSTALLATION
NOTE: Pages 28-29 have information
on restrictor installation in
conjunction with venting installation.
Page 57 has information on restrictor
recommendations depending on
burner flame appearance and
instructions on installation after
venting is completed.
VENTING
THE HORIZONTAL
.
TERMINATION CAP