VERTICAL VENTING (rear vent)
Figure 22a
CAUTION: This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
NOTE: Flange on top stand-off must be bent upwards to a 90˚ angle when top venting.
RESTRICTOR INSTALLATION
TO BE USED AT INSTALLER DISCRETION.
Large Restrictor
Remove tab (s) to
create small restrictor
Figure 22c
NOTE: Page 51 has information on restrictor recommendations depending on burner flame appearance and instructions on installation
after venting is completed.
VENTING
TERMINATION CAP
MIN. 14"(356 mm)
MAX. 22 ft (7.71m)
90° ELBOW
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
MAXIMUM VERTICAL VENTING (top vent)
TERMINATION CAP
Figure 22b
Slide restrictor into exhaust pipe on top of fireplace with tabs
pointing towards you prior to attaching venting.
PAGE 22
MAX. 33 ft.(10.06 m)