Typical Corner Installation; Vertical Vent System Clearances; Vertical Min. / Max. Venting Illustrations - kozy heat Delano DEL-36 Installation And Operation Manual

Direct vent linear fireplace
Table of Contents

Advertisement

HORIZONTAL VENTING
NOTE: Horizontal sections require 1/4" (6mm) rise for every
12" (305mm) of travel.

TYPICAL CORNER INSTALLATION

90° elbow + horizontal pipe + termination cap.
(Horizontal Vent Heat Shield required).
VENTING DIMENSIONS FOR MINIMUM CORNER
INSTALLATIONS
Vent Opening Dimensions: 12-1/2" (318mm) H x 10-7/8" (276mm)
From Floor or Hearth to Vent Opening Center: 37-7/8" (962mm)
From Corner to Vent Opening Center: 15-7/8" (403mm)
ALL APPROVED RIGID PIPE
KOZY HEAT #800 SERIES
VERTICAL TERMINATIONS
MIN. / MAX. VERTICAL VENTING
MINIMUM: 4ft. (1.22m) + cap.
MAXIMUM: 40ft. (12.19m) + cap.
NOTE: Horizontal Vent Heat Shield is not used on vertical
venting configurations.
VENTING

VERTICAL VENT SYSTEM CLEARANCES

TOP
1 inch (25mm)
DO NOT USE FOR VERTICAL TERMINATIONS
PAGE 18
TERMINATION CAP
PIPE
90° ELBOW
Figure 18a
BOTTOM
1 inch (25mm)
MINIMUM: 4ft. (1.22m)
MAXIMUM: 40ft. (12.19m)
Figure 18b
SIDES
1 inch (25mm)
TERMINATION CAP