ELECTRICAL WARNING AND INFORMATION:
Electrical wiring must be installed by a licensed electrician.
Do NOT wire 110V to wall switch.
Uninterrupted or continuous power is required at all times in IPI systems EXCEPT when using battery back-up.
Incorrect wiring will override IPI safety lockout and may cause an explosion.
Disconnect 110V before servicing
A double receptacle box cover and (3) wire nuts are supplied in fireplace components packet to be used when hardwiring to electrical box
located under firebox on right side of fireplace. Ensure receptacle box cover is installed with flange to top.
ATTENTION: THIS SYSTEM GOES THROUGH A CALIBRATION MODE WHEN SWITCHING FROM „ON‟ TO „THERMO‟ TO
„OFF‟ MODES, CREATING A HUMMING SOUND WHICH IS A NORMAL PART OF OPERATION.
CONTINUOUS PILOT (
The IPI gas control system has the option of a continuous (standing) pilot feature. This allows you to change from a spark-to-pilot
system to a standing pilot system during cold weather conditions. By having the pilot on continuously, the firebox will remain warm
and a draft is established in the vent, allowing the main burner to turn on with less air-flow disruption.
When continuous pilot mode is activated and fireplace is turned ON, the pilot will spark and light. When fireplace is turned OFF, the pilot
will remain lit when main burner has been turned OFF.
This pilot feature can be activated or de-activated by the hand held remote control transmitter. Instructions on following page.
OPERATION USING BATTERY POWER
This fireplace has an optional battery operation if electrical power is lost. Position battery pack with four "AA" size batteries installed
between valve and front of fireplace. This is the coolest location under firebox, ensuring longer battery life.
NOTE: When operating fireplace in this capacity, the only function available is flame modulation.
MATCHING SECURITY CODES
Before matching security codes make sure 120V AC is connected and powered
to fireplace, and hand held remote control is installed with (2) AA batteries.
It may be necessary to program main control module to LEARN the security
code of the hand held remote control upon initial use, if batteries are replaced, or
if a replacement remote control is purchased from your dealer.
1.
When matching security codes, be sure slide button on main control module
is in REMOTE; the code will not "LEARN" if slide is in OFF.
2.
Program main control module to LEARN a new security code by pushing in
LEARN button on main control module using a pencil point for 2 seconds
(you should hear a single „beep‟ letting you know module is ready to learn a
new code).
3.
Press MODE button on hand held remote control (you should hear four
„beeps‟ in rapid succession in main control module, indicating remote
control‟s code has been programmed into the main control module). When
an existing main control module is introduced to a new hand held remote
control, the new security code will overwrite the old one.
If it ever becomes necessary to clear the memory from the hand held remote
control, simply push and hold the LEARN button for 10 seconds (you should
hear three long beeps in succession). You may now follow steps outlined above
to „RE-LEARN‟ security codes.

56701-IPI INFORMATION

FOR VERY COLD CONDITIONS)
PAGE 42
LEARN BUTTON
SLIDE TO REMOTE POSITION
Figure 42a