Control Board Removal - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

CAUTION: If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before
removing any components.
NOTE: Illustrations shown with 56701 valve components.
1.
Model 56701
Turn gas control knob to „OFF‟.
Model 56701-IPI:
Use remote to turn fireplace off.
2.
Shut off gas supply at manual shut-off valve.
3.
Disconnect gas line flex tube from manual shut-off valve.
4.
Model 56701:
Disconnect any wall switch, remote control or thermostat wires
from top & bottom terminals on gas valve.
Model 56701-IPI:
Unplug all components from receptacle, disconnect all wiring
harnesses attached to gas valve.
5.
Remove upper hood and upper louver. Page 32.
6.
Remove glass frame assembly. Page 12.
7.
Remove logs, pilot shield and bottom refractory panels.
LP gas models: Remove LP log plate.
8.
Remove refractory panel set (if installed).
9.
Remove burner tube from firebox by lifting up off tabs, sliding
to left & off orifice.
10. Remove front log supports. Save supports and screws.
11. Remove log grate/burner heat shield.
12. Remove and save (6) screws securing control board, lift board
out of firebox being careful not to damage sealing gasket lying
underneath.
LP GAS MODEL: LP LOG PLATE
Figure 30a

CONTROL BOARD REMOVAL

BURNER TUBE
FRONT LOG SUPPORTS
LOG GRATE / BURNER HEAT SHIELD
REMOVE (6) SCREWS
Figure 30b
PAGE 30
PILOT SHIELD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thief river falls 56701-ipiThief river falls 56701

Table of Contents