#56701 COMPONENTS LIST
PART NUMBER
TRF-770
Millivolt Board Assembly
700-203
Manual Gas Shut-off Valve
TRF-030
Burner Cover
TRF-035
Burner Tube
TRF-500A
Log Package
TRF-057T
Glass Frame Assembly
OCK-S625A
LP Conversion Kit
600-083
Receptacle / Speed Control Assembly
900085
4" Restrictor Plate
500-TRF
3 pc. Grill Assembly
INSTALLATION OVERVIEW
NOTE: The qualified installer should follow the procedure best suited for the installation.
1.
Frame an opening for the fireplace, allowing for vent installation (top or rear) and type of installation (corner or flat wall application).
2.
If masonry (optional) is used, prepare foundation for the masonry load. A lintel is required to support the added weight above fireplace.
3.
Attach nailing flanges to fireplace.
4.
Insert fireplace into framing.
5.
Install hearth (if applicable).
6.
Complete gas line installation.
7.
Complete electrical hook-up. Install any standard or optional electrical components at this time.
8.
Complete venting installation.
9.
Secure fireplace to flooring through holes in outer box bottom and to framing with nailing flanges. Verify all clearances at this point.
10. Install facing material, mantel or cabinetry, allowing room for optional full face doors, if applicable.
11. Install optional refractory.
12. Install logs.
13. Install grills and optional decorative doors / faces.
14. Verify proper operation of fireplace and all components.
PLACEMENT CLEARANCE REQUIREMENTS
This fireplace must be installed on a level surface capable of supporting the fireplace and venting.
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of
fireplace.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.
SPECIFICATIONS
DESCRIPTION
#56701-IPI COMPONENTS LIST
PART NUMBER
TRF-600-IPI
700-203
TRF-030
TRF-035
TRF-500A
TRF-057T
OCK-A625L-I-TRF-PSE
600-002
900085
500-TRF
IPI-028
700-208
PAGE 7
DESCRIPTION
Control Board Assembly
Manual Gas Shut-off Valve
Burner Cover
Burner Tube
Log Package
Glass Frame Assembly
LP Conversion Kit
Double Receptacle Assembly
4" Restrictor Plate
3 pc. Grill Assembly
IPI Fan Kit
Remote Control