Framing; Wall Enclosure Rough Opening; Minimum Finished Opening Dimensions - kozy heat 56701 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

WALL ENCLOSURE ROUGH OPENING

IMPORTANT: Framing dimensions should allow for wall covering thickness and fireplace facing materials. If using a hearth, adjust
rough opening size as necessary to maintain at least minimum clearance requirements.
IMPORTANT: NON-COMBUSTIBLE FACING MATERIAL MAY BE APPLIED OVER (BUT NOT DIRECTLY TO) FIREPLACE FACE. THIS
WILL PREVENT FACING MATERIAL FROM FALLING OFF DUE TO HEAT EXPANSION. DO NOT OBSTRUCT THE FLOW
OF VENTILATION AIR.

MINIMUM FINISHED OPENING DIMENSIONS

(APPLIES TO BOTH HORIZONTAL AND VERTICAL VENTING TERMINATIONS)
38-1/4"(972 mm) High x 41-1/4"(1084 mm) Wide x 16-1/4" (413 mm) Deep.
1/2" (13 mm) clearance at back and sides of fireplace must be maintained.
NOTE: Provide adequate clearance in front of fireplace to operate lower grill, open and close optional decorative doors / full door faces,
access components, installation of gas line, fan, etc.
WARNING: DO NOT OBSTRUCT UPPER AND LOWER GRILL OPENINGS. ROOM AIR ENTERS THROUGH LOWER PASSAGE, IS HEATED
AND EXITS THROUGH UPPER PASSAGE. BLOCKING THESE PASSAGES MAY RESULT IN OVERHEATING, CREATING A
POTENTIALLY HAZARDOUS SITUATION.
(972 mm)
Figure 9a

FRAMING

38-1/4"
41-1/4"
(1084 mm)
16-1/4"
(413 mm)
PAGE 9